Safety Information
When using NaviTEK NT, always take basic safety precautions to reduce the risk of fire,
electric shock and injury to persons. These include the following:
•
When connecting to the port, special care must be taken as high voltages may be
present and there may be a danger of electrocution.
•
Avoid using the tester during an electrical storm - there is a remote risk of electric
shock by lightning.
•
Use only the mains electricity adaptor supplied with your NaviTEK NT.
DO NOT CONNECT ANY TELECOMMUNICATIONS NETWORK
Power and Maintenance
NaviTEK NT can be powered from:
•
A rechargeable power module,
•
Directly from power connected to the DC inlet built in to the power module.
•
An optional non-rechargeable battery pack
Power Module Management
A fully charged power module will support up to five hours of heavy, continuous use. For
maximum life of the power module it is recommended to discharge it fully and then recharge
it fully at least once a month. The power module is not user-serviceable. When it has reached
the end of its life, please contact your local IDEAL representative for service.
Power Module Recharging
The power module can be fully recharged in three hours with the NaviTEK NT switched ON or
OFF. To recharge the power module, connect the supplied power adaptor to the DC inlet.
For convenience the power module may be removed from, or left attached to, the unit for
charging. The Power LED next to the DC inlet glows green to show that the battery is being
charged, and flashes green to show that it is not being charged. The power module charge
state is indicated at FULL, 2/3, 1/3 and EMPTY by the graphical power meter shown in the
display's information bar at the top of its LCD display.
Switching ON and OFF
To switch ON the tester, press the ON/OFF button. A splash screen showing the IDEAL logo
and model identity is shown on the display. The home screen is then shown on the display and
NaviTEK NT automatically searches for a network to test.
To switch OFF, press and hold the Power button for approximately 1/2 second, a shutdown
message is displayed on the screen. The currently stored setup is saved. If the unit does not
switch OFF within five seconds of pressing the Power button, please see Master Reset.
Always switch OFF the unit before removing the power module.
Caution
Do NOT remove the power module when the tester is switched on.