Replacing The Hydraulic Filters - Toro Reelmaster 5610 Owner's/Operator's Manual

Traction unit
Hide thumbs Also See for Reelmaster 5610:
Table of Contents

Advertisement

1.
Park the machine on a level surface, lower the
cutting units, engage the parking brake, shut off
the engine, and remove the key.
2.
Raise the hood.
3.
Place a large drain pan under the fitting secured
to the bottom of the hydraulic-fluid reservoir
(Figure
68).
Figure 68
1. Hose
4.
Disconnect the hose from the bottom of the
fitting and let the hydraulic fluid flow into the
drain pan.
5.
Install the hose when hydraulic fluid stops
draining.
6.
Fill the reservoir with hydraulic fluid; refer to
Hydraulic Fluid Specifications (page 47)
Hydraulic Fluid Capacity (page
Important:
Use only hydraulic fluids
specified. Other fluids could cause system
damage.
7.
Install the reservoir cap.
8.
Start the engine and use all of the hydraulic
controls to distribute hydraulic fluid throughout
the system.
9.
Check for leaks.
10.
Shut off the engine.
11.
Check the level of the hydraulic fluid and add
enough to raise level to the Full mark on the
dipstick.
Important:
Do not overfill the reservoir.
Replacing the Hydraulic
Filters
Service Interval: Every 1,000 hours—If you
The hydraulic system is equipped with a service
interval indicator
at operating temperature, view the indicator, it should
be in the green zone. When the indicator is in the red
zone, change the hydraulic filters.
g004139
1. Hydraulic filter restriction indicator
and
47).
Important:
warranty on some components.
1.
2.
48
are using the recommended
hydraulic fluid, replace the
hydraulic filters.
Every 800 hours—If you are not using the
recommended hydraulic fluid or have ever
filled the reservoir with an alternative fluid,
replace the hydraulic filters.
(Figure
69). With the engine running
Figure 69
Use of any other filters may void the
Park the machine on a level surface, lower the
cutting units, engage the parking brake, shut off
the engine, and remove the key.
Clean the area around the filter mounting area
and place a drain pan under the filter
and
(Figure
71).
g004132
(Figure
70)