9 ALU Key-Press to select desired balancing mode.
7 Key- Press to recalculate weight amount to be attached to the wheel; Or hold this key to
perform Calibration (see the chapter of calibration).
1Wheel offset (a) enter keys –press to enter wheel offset a( The distance between the inner
rim flange and the edge of the balancer.)
2Rim Width (b) enter keys –press to enter rim width b
3Rim diameter (d) enter keys –press to enter rim diameter d
10 OPT Key-press to optimize weight to be attached to the wheel.
8
F key- press to select static or dynamic balancing mode.
CAUTION: Press the keys with finger only, NEVER use other hard parts to press keys.
7.3 Function switching keys
7.3.1 The following function switches will be saved to memory and kept after system power
off. Gram –Oz unit switching : press the key [F] and [a↓] at the same time when the amount of
weights need to attached on the rim was displayed.
2) SPIN MODES
Manual - Operator closes the hood and must press [START] to initiate the spin cycle.
Automatic - Operator close the hood and balancer automatically initiates the spin cy-
cle. Important –
A. In calibration mode the spin function is always set to manual.
B. The standard factory setting is automatic.
To change between manual and automatic spin modes and vice-versa the following steps are
required.
Press and hold [F] then press [STOP]. All lights on touch panel will turn off. After 5 seconds re
-lease [F] and [STOP] and lights on touch panel will turn on. This is the confirmation that the
spin mode has been changed.
7.3.2 The following function switching will not be kept after system power off.
Inch/mm unit switching:
1.for rim width b, press and hold the key [F] , then [b↑] or [b↓]
2.For rim diameter d, press and hold the key [F] , then [d↑] or [d↓]
Remarks: the default unit for each start up of the machine is inch.
7.3.3 Mode switching.
Press key [F] to toggle between modes: Dynamic  Static
Press key [ALU] to toggle between modes: ALU-sALU-1ALU-2ALU-3
ALUs
Calibration press and hold the key [F] , then [C]
8.To Mount A Wheel Onto The Balancer
Connect the Plug of the Power Cord into a properly grounded, 3-hole, electrical receptacle.
Insert the center hole of the wheel rim (not provided) onto the Transmission shaft (part #24).
Make sure to position the inner side of the wheel rim against the Flange (part #23).