Download Print this page

Festool SYSLITE KAL II Original Operating Manual page 11

Hide thumbs Also See for SYSLITE KAL II:

Advertisement

5
Machine features
[1-1] Charging state indicator LED
[1-2] ON/OFF switch with 3 settings
[1-3] Folding attachment handle
[1-4] Connecting socket for charging
adapter
[1-5] Magnetic foot with spherical
head  *
[1-6] Adapter plate *
[1-7] Specific charging adapter for
country *
[1-8] Vehicle charging adapter
[1-9] Mains charging adapter *
[2-1] Threaded socket for tripod UNC
1/4"-20
* not on all versions included in the
scope of delivery
6
Operation
Prior to initial operation: charge
battery pack for approx. 4 h.
6.1 Charging the internal battery
pack
X Insert the mains or vehicle charging
adapter into the connecting socket
[1-4].
When the light is switched off, the
charging state indicator LED [1-1]
displays the operating state of the
internal battery for the duration of the
charging process:
LED green - flashing quickly
Charging internal battery at maximum
rate.
LED green - flashing slowly
80% of internal battery capacity
exceeded.
LED green - continuous light
Internal battery is charged to 90% and
then charged fully at reduced power.
LED red - flashing
General fault indication, e.g. incomplete
contact, short circuit, battery faulty.
LED red - continuous light
Battery temperature is outside the
permitted range.
LED orange
Power failure mode, see chapter 6.5.
6.2 ON/OFF switch [1-2]
The ON/OFF switch [1-2] has three
settings:
– Press once -> Switch on in lighting
mode in energy-saving stage
(Stage1: 30%)
– Press twice -> Switch to max.
luminosity (Stage 2: 100%)
– Press three times -> switch off
6.3 Voltage monitoring
If the minimum operating voltage is not
met during lighting mode with either
internal or external battery pack, the
device shifts to emergency mode. It
reduces luminosity and switches off
after 2minutes.
6.4 Temperature monitoring
If the device temperature does not
remain within the specified limits, the
working light switches to emergency
mode. It reduces luminosity and then
switches off after 2 minutes.
6.5 Power failure mode
The working light has a power failure
mode. It automatically lights up the
work area in the event of a sudden
power failure.
X Hold down the ON/OFF switch
[1-2] and insert the mains charging
adapter or car charging adapter in
the connector socket [1-4].
KAL II
11

Advertisement

loading