Ebyte E103-W01-IPX User Manual
Ebyte E103-W01-IPX User Manual

Ebyte E103-W01-IPX User Manual

2.4ghz 100mw smd wireless module

Advertisement

Quick Links

E103-W01-IPX User Manual
ESP8266EX 2.4GHz 100mW SMD Wireless Module

Advertisement

Table of Contents
loading

Summary of Contents for Ebyte E103-W01-IPX

  • Page 1 E103-W01-IPX User Manual ESP8266EX 2.4GHz 100mW SMD Wireless Module...
  • Page 2: Table Of Contents

    Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual CONTENTS 1 General Introduction ............................. 2 1.1 Brief Introduction ....................................2 1.2 Features ........................................2 1.3 Application ......................................2 2 Specification and parameter .......................... 3 2.1 limit parameter....................................... 3 2.2 Operating parameter ..................................... 3 3 Size and pin definition ..........................
  • Page 3: General Introduction

    E103-W01-IPX User Manual 1 General Introduction 1.1 Brief Introduction E103-W01-IPX is 100mW (20dBm) UART wi-fi module with competitive price. It is small-size with both IPX and ceramic antenna, operating at 2.4~2.4835GHz, The module can use the serial port for data transmission and reception, and very easy for user to operate.
  • Page 4: Specification And Parameter

    Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual 2 Specification and parameter 2.1 limit parameter Performance Main parameter Remark Voltage over 3.6V will cause Power supply (V) permanent damage to module Chances of burn is slim when modules Blocking power(dBm)...
  • Page 5: Size And Pin Definition

    Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual 2.5m AT Support Built-in intelligent processing Can be read by AT command Communication interface UART Serial port Package Interface 2.00mm Size 16 * 24 mm Antenna Ceramic antenna / IPEX 50 ohm impedance...
  • Page 6 Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual GPIO12 PWM0/GPIO12 GPIO13 GPIO13 Power supply VDC:3.0V—3.6V(above 300mA) GND pin Boot GPIO15 GPIO15 GPIO2 ★ GPIO0 Boot from GPIO2 FLASH Download GPIO0 firmware from UART GPIO4 PWM2/GPIO4 GPIO5 PWM3/GPIO5 UART input pin, support AT command UART output pin, support AT command ★...
  • Page 7: Recommended Connection Diagram

    5 Quick Start  E103-W01-IPX module is easy to use. In order to allow users to quickly familiarize themselves with the module, this section will guide the user through simple setup to achieve configuration and communication in various modes. ...
  • Page 8: Connected To Tcp Server As Client

    Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual PC with wi-fi Router*1(Mobile wi-fi hotspots) Software(download from our official website) E103-W01 configuration software TCP&UDP testing tool Accessport 1.3 5.1 Connected to TCP server as Client Remarks 【Network connection】 : Computer connected to router, and the router named H60-L02(configurable for user) Noted the IP address as 192.168.1.50...
  • Page 9 Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual 【Module installation】 : Substrates VCC short jumper, GPIO0 jumper disconnected. Plug E103-W01 into test baseboard. Plug the baseboard into PC by USB connector (Please download CP1202 driver if the PC cannot recognize baseboard).
  • Page 10 Serial port status changes to open now, click “STATION” button to enter configuration interface. The test router name as Ebyte, password is e30e31e32. Click “enter Sta mode” to change the mode to STATION. Click “connect to router”, and wait a few seconds to see the interface shown in the figure below, which means module is connected to the router successfully.
  • Page 11 Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual 【Transmitting】 : Use AT+CIPSEND command to transmit data, first send AT+CIPSEND=6 to specify the length of 6 bytes. Copyright ©2012–2018,成都亿佰特电子科技有限公司...
  • Page 12 Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual After “>” symbol shows, transmit data “123456”, user can see the TCP server receive data "123456". Data communication completed.. Copyright ©2012–2018,成都亿佰特电子科技有限公司...
  • Page 13 Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual 【Transparent transmission】 : After the configuration, module can transmit data to TCP server directly without AT protocol. Configuration: click “enter transparent transmission mode”(AT+CIPMODE=1) after connected to server, then input AT+CIPSEND to enter transparent transmission mode.
  • Page 14 Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual 【Transparent transmission on power-up】 : Advantage: save the complicated operation steps for user, once the configuration for transparent transmission on power-up is done, transparent transmission can be achieved on power-up. After using this function, user only need to configure the connection between router and TCP once.
  • Page 15 Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual Input server IP address, port number, and choose TCP mode, then click “transparent transmission on power- up”, see below interface means configuration is done After click “re-start” or re-power the module, it will connect to the router and address automatically and the connection status can be judged by wi-fi indicator (GPIO2).
  • Page 16 Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual Wi-Fi indicator(GPIO2) specification: Intermittent double flash:cannot connect to AP access point. Intermittent single flash:connect to AP access point, but cannot connect to TCP server. Quench:connect to AP access point and TCP server.
  • Page 17: Module Build Tcp Server To Connect To Pc As Ap

    Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual 【Exit transparent transmission】 : Send “+++” to exit transparent transmission mode and re-enter AT mode. After exiting transparent transmission mode, user can use AT command to exit transparent transmission on power-up mode. See below, Click “exit transparent transmission”...
  • Page 18 Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual 【Module recommends TCP server】: Make sure PC is connected to the modules, then click "server settings" button. Click “open multiple connections”(exiting transparent transmission mode is necessary) first, then click “built server” to see below information.
  • Page 19: Usage Of Smart Config

    Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual 5.3 Usage of Smart Config Remark Smart Config enable user to use phone APP to configure module and connected with network with fast-speed. When module works at STATION mode, send“AT+CWSTARTSMART” to enter Smart Config mode,then the configuration for module can be done by cellphone.
  • Page 20: Usage Of Pwm

    APP to make connection between module and router. 5.4 Usage of PWM Steps E103-W01-IPX supports 4 channel PWM output, can be configured through the AT instruction to fast PWM cycle (1~10ms) and duty cycle, Steps: enter "peripheral control option" to configure parameters: Period range 1000~10000 corresponds to 1ms~10ms Copyright ©2012–2018,成都亿佰特电子科技有限公司...
  • Page 21 Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual Adjustment for duty cycle value Range of 0~222222 corresponding to 0ms~10ms (high level time≈value*45ns) Channel number range 1~4 indicates the number of currently enabled PWM channels, increasing from PWM0, for example channel number is equal to 2, then PWM0 and PWM1 are enabled(channel number cannot be...
  • Page 22: Usage Of Gpio

    5.6 Usage of ADC Remark E103-W01-IPX provides one ADC with 10-byte precision, with which 0.0V ~ 1.0V voltage can be detected. User can get current ADC value by AT command (AT+EBADC), then obtain the real voltage by calculation. Input voltage=ADC value/1024 For example ADC value is 45, so the really voltage is equal to45/1024=0.044V.
  • Page 23: Modify Uart Baud Rate

    5.7 Modify UART baud rate Remark E103-W01-IPX module supports 10 standard UART baud rate. The user must not set the baud rate out of the effective range, or there will be an issue when debugging . If so, please reload the firmware or contact us for help.
  • Page 24: Specification For Networking

    6 Specification for networking 6.1 Wi-fi role Remark E103-W01-IPX supports AP mode (router) and STATION mode (wi-fi equipment). At most 3 wi-fi devices can be supported when module works at AP mode. E103-W01-IPX including TCP Server、TCP Client and UDP as Socket.
  • Page 25 Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual Module build TCP Client to connect with wi-fi device when works at STATION mode The same as type one, only difference is module build TCP server instead of TCP Client when works at STATION mode.
  • Page 26 Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual One module build TCP Server when works at AP mode, and the other module build TCP Client when works at STATION mode to communicate with it. The network model can be referred to as intra-module networking. A module in an AP mode can connect up to three STATIONs, that is, up to four module devices in the network.
  • Page 27: At Command

    Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual 7 AT command Only list some special AT command for your reference, more AT command please refer to the official datasheet. AT+EBPWM-PWM Set or modify Parameter specification: channel_num:channel number period:cycle(1000~10000corresponding to1~10ms)...
  • Page 28: Hardware Design

    Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual Parameter specification: Setting to 1 indicates set GPIO13 as wi-fi status indicator. AT+EBSTATE=<en> Setting to 0 indicates cancel for set GPIO13 as wi-fi status indicator. Response:OK Example:AT+EBSTATE=1 Notes:After setting GPIO13 as wi-fi indicator, the IO operation is forbidden.
  • Page 29: Faq

    Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual 9 FAQ 9.1 Communication range is too short  The communication distance will be affected when obstacle exists;  Data lose rate will be affected by temperature, humidity and co-channel interference;...
  • Page 30: Reflow Soldering Curve

    Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual Preheating time Preheat Time (Tsmin to Tsmax)(ts) 60-120 sec 60-120 sec Average ramp-up rate Average ramp-up rate(Tsmax to Tp) 3℃/second max 3℃/second max Liquidous Temperature (TL) Liquid phase temp 183℃ 217℃...
  • Page 31: Antenna Recommendation

    Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual E103-W02 CC3200 2.4G 802.11b/g/n 19 * 27 PCB/IPX E103-W01 ESP8266EX 2.4G 802.11b/g/n 16 * 24 12 Antenna recommendation 12.1 Recommendation The antenna is an important role in the communication process. A good antenna can largely improve the communication system.
  • Page 32: Package

    Chengdu Ebyte Electronic Technology Co., Ltd. E103-W01-IPX User Manual 13 Package Revision history Version Date Description Issued by Initial version 1.00 huaa 1.10 2018-5-25 Content update huaa 1.20 2018-11-2 new version update Huaa Copyright ©2012–2018,成都亿佰特电子科技有限公司...
  • Page 33: About Us

    E103-W01-IPX User Manual About us Technical support: support@cdebyte.com Documents and RF Setting download link::www.ebyte.com Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com ------------------------------------------------------------------------------------------------- Office Hotline:028-64146160 ext. 821 Web: www.ebyte.com Address: Innovation Center D347, 4# XI-XIN Road,Chengdu, Sichuan, China...

This manual is also suitable for:

Esp8266ex