Ebyte E103-W06 User Manual
Ebyte E103-W06 User Manual

Ebyte E103-W06 User Manual

Cc3235sf 2.4g/5.8g dual frequency wifi serial port module

Advertisement

Quick Links

E103-W06 User Manual
CC3235SF 2.4G/5.8G Dual Frequency WiFi Serial Port Module

Advertisement

Table of Contents
loading

Summary of Contents for Ebyte E103-W06

  • Page 1 E103-W06 User Manual CC3235SF 2.4G/5.8G Dual Frequency WiFi Serial Port Module...
  • Page 2: Table Of Contents

    5.13 D ..................................14 EFAULT PARAMETERS 6. USE TUTORIAL ............................16 6.1 B TCP/UDP ..............................16 ASIC DATA TRANSFER 6.1.1 Communication with PC ................................16 6.1.2 Communication between modules ............................24 6.2 T ..................................29 ELECOMMUNICATION Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 3 ....................................35 ODBUS USAGE 6.5 S ....................................36 TATIC USAGE 7. WELDING OPERATION GUIDANCE ....................36 7.1 R ..................................36 EFLOW TEMPERATURE 7.2 R ....................................37 EFLOW PROFILE 8 REVISE HISTORY ............................37 ABOUT US ..............................38 Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 4: Overview

    Smartconfig convenient Sexual distribution network function. E103-W06 is an industrial-grade WIFI module that truly combines ease of use with high reliability and high performance.
  • Page 5: Application

    2. Parameter 2.1 Limit parameter Performance Main parameter Remark Min. Max. voltage(V) Exceeding 3.6V will permanently burn the module blocking power(dBm) The probability of burning at close range is small Operating temperature(℃) Industrial grade Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 6: Working Parameter

    Average power consumption received 78mA consumption (2.412GHz) receive current(mA) Average power consumption 83mA received(5.18GHz) 18uA hibernate sleep current(μA) 18uA Low power deep sleep(LPDS) WiFi version 802.11 a/b/g/n Pad size 0.81mm*0.81mm, 50Ω RF interface characteristic impedance Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 7: Size And Pin Definition

    GPIO12 General IO port GPIO13 WAKEUP wakeup pin GPIO22 General IO port JTAG_TDI JTAG emulation pin, JTAG TDI input; not connected if not used FLASH_SPI_ External serial FLASH programming interface: SPI data input Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 8 VBAT2). The leakage current is expected to be (3.3 V/ 100 kΩ) mA due to the internal pull-up resistors. Powe VBAT1 37,39 Module power positive reference, voltage range 2.3 V to 3.6 V. Note: Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 9 Ground wire, connected to the power reference ground Ground wire, connected to the power reference ground Ground wire, connected to the power reference ground Ground wire, connected to the power reference ground Ground wire, connected to the power reference ground Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 10: Recommended Wiring Diagram

    2、 Pin 40 VBAT2 and Pin 37 VBAT1 inside the module are not connected, and need to be short-circuited with Pin 37 VBAT1 when using. 3、 RXD/TXD of E103-W06 are connected to MCU_TXD/MCU_RXD of external MCU respectively. 4、 nRESET pin has built-in 100K pull-up resistor to VBAT_RESET pin. Note: VBAT_RESET is not connected to VBAT1 or VBAT2 inside the module.
  • Page 11: Job Role

    Transparent transmission means that when only one socket is supported, data from either the serial port or the network is sent directly without any format. Command AT+MODE=x.1,x set the second bit to 1 to configure the module to work in transparent transmission mode. Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 12: Protocol Transmission

    0x00,Represents the discovery of a Socket 0 link 0x01,Delegate discovers Socket 1 link 0x02,Represents the discovery of a Socket 2 link 0x03,Represents discovery of Socket 3 link length: The actual length of the application data, range: 0~1000 Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 13: Service Mode

    For network communication based on Alibaba Cloud platform, you need to log in to Alibaba Cloud to obtain relevant parameters, which mainly include product secret key, device name, client ID and other information. For details, see Chapter 7 Alibaba Cloud Configuration Tutorial. Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 14: Http Client

    The application of the WebSocket function allows the E103-W06 module to pass the serial port. Real-time interaction with the web page saves the GET and POST request process initiated by the HTTP client during multiple interactions, improves the response speed, and the module side can actively push data to the web page.
  • Page 15: Udp Remote Configuration

    Chengdu Ebyte Electronic Technology Co., Ltd. E103-W06 User Manual For specific AT commands, please refer to "E103-W06 AT Command Manual". 5.4.2 UDP Remote configuration UDP remote configuration is a parameter configuration performed by using a network debugging tool under the same network, which can also be called over-the-air configuration.
  • Page 16: Heartbeat Package, Registration Package

    There is no need to restart when using, and the GPIO14 pin will be set to low level after the parameters are restored successfully. Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 17: Scan Nearby Ap Information

    Whether to hide SSID 0(no) encryption type 2(WPA2) password 12345678 job role AT+MODE Operating mode transfer mode service mode IP address 10.145.45.1 AT+NETIP network IP subnet mask 255.255.255.0 address gateway address 10.145.45.1 server address 10.145.45.1 Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 18 CK-STR NTP time NTP timezone offset 480 (unit: minutes) Beijing AT+NTPTIME time Modbus Modbus enabled 0(close Modbus) AT+MODBUS static IP IP address 10.145.45.2 AT+IPSTATIC subnet mask 255.255.255.0 gateway address 10.145.45.1 server address 10.145.45.1 Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 19: Use Tutorial

    1、Set the module role: AP, transmission mode: transparent transmission, service mode: TCP server; AT+MODE=1,1,1 2、Configure SSID related parameters (SSID is commonly known as WiFi name): AT+SSID=0,E103-W06-TEST,2,12345678. 3、Set working frequency: AT+RADIO=1,36,0,0,CN 4、Set IP address: AT+NETIP=192.168.1.111,255.255.255.0,192.168.1.31,192.168.1.31 5、set port number: AT+SVRPORTIP=4001 Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 20 6、*After configuring the parameters, restart the module, find the WiFi with the SSID (WiFi hotspot name) set in the second step called E103-W06-TEST on the PC side, and enter the secret connection 7、*After the connection is successful, query the local IP and local port:...
  • Page 21 1、*Turn on the mobile phone hotspot, connect the PC to the hotspot, and find the IP address assigned to the PC by the hotspot. This step is very important. If the IP address is incorrect, communication will not be possible. (can also be connected to a router). Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 22 5、*Set the connection target parameters, the parameters here are the hotspot name, password and encryption method set in the first step: AT+STACON=ebytew06,2,12345678 6 、 *Set the connection method (connection is divided into manual, automatic, smartconfig), here select automatic connection: AT+CONTYPE=1 Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 23 1、* Set Role: AP, Transmission Mode: Protocol Transmission, Service Type:UDP AT+MODE=1,2,3 2、* Set the local port number AT+ SVRPORTIP=4001 3、*Set UDP communication list, this step is to distinguish UDP data source, you can set 4 groups. Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 24 This is just for demonstration, the actual value can be set by itself as needed. 4、* Reboot the module, use a PC to connect to the module 5、* Open UDP Assistant to establish UDP communication Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 25 Protocol Transmission for details. The PC side does not need to be formatted, but the module will print out the data according to the protocol format after receiving the data from the PC side. module send: Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 26 It should be noted that if the source address and port of the received data are not in the parameters set in the third step, the serial number spit out is 0xff, indicating an unidentified data source. Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 27: Communication Between Modules

    Get the local IP: AT+SVRPORTIP? (Be sure to do this here, and then pass the parameters into the STA, otherwise it will not be able to communicate). The return value is shown in the figure. Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 28 Target:AT+STACON=E103-W06,2,12345678 Set the remote IP and port, here the IP and port obtained by STA1 are passed in: AT+SOCKET=0,4001, 192.168.0.189 Restart the module and wait for the connection to complete before communicating. Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 29 Set the local port: AT+SVRPORTIP=4002 (note that the local port here is the remote port in the previous step). Set the remote port remote IP: AT+SOCKET=0,4001,10.145.45.1 (the remote port IP here is the local port IP in the previous step). Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 30 2、*Then select one of the modules and configure it as GroupOwner, and send commands to set connection parameters (see Configuration, Read WiFi-Direct (P2P) connection parameters for instruction descriptions): AT+P2PDEVINFO=20,1,E103-W06WiFiDirectGo,E103-W06WiFiDirectClient 3、Query the socket local port and IP address (or): AT+P2PSOCKET? Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 31 Client (the IP address and port of this part must be obtained after querying the GroupOwner, otherwise communication cannot be established) AT+SVRPORTIP=4001,10.145.45.1 6、*Restart and wait for the connection to be established to communicate Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 32: Telecommunication

    4、 Device Name: The device name entered when adding the device. Note: Only numeric English can be input, and the input length cannot exceed 10 bytes 5、 Client ID: User-defined input. Note: Only numeric English can be input, and the input length cannot exceed 12 bytes Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 33 6、 Address: Domain name connected to Baidu Internet of Things. Such as:Un2d6cs.mqtt.iot.gz.baidubce.com 7、 port:Baidu IoT Port。Such as:1883 8、 Subscribe to topics:Such as:$baidu/iot/general/get 9、 Post topic:Such as:$baidu/iot/general/update 10、 Subscribe to publish message level:Qos:0 、Qos:1 、Qos:2 Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 34 3、 Device ID: such as: 511986588 4、 Product ID: such as: 286258 5、 Authentication information: custom input when creating a device. Such as: ebyte 6、 Address: The domain name for accessing the ONENET Internet of Things. Such as: mqtt.heclouds.com 7、 Port: ONENET IoT port. Such as: 6002 8、...
  • Page 35: Http Client

    192.168.4.10:8080 is the HTTP server address and port. Custom protocol header: The default is Connection: keep-alive, the user can modify, if you need more than one, add \r\n between commands, the last one is not added. Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 36: Websocket

    Serial AT command configuration, directly open the serial debugging assistant, set the corresponding baud rate, data bits, etc. Configure according to the AT command in Chapter 6. It should be noted that the command must follow the Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 37: Udp Remote Configuration

    IP address used for demonstration. Use the command: AT+SVRPORTIP? to query and enter the correct IP to enter the configuration interface. The IP address is set according to the module feedback results, and other parameters are set according to their own needs. Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 38: Modbus Usage

    After setting the working parameters according to the above chapters, enter the AT command and open the modbus protocol: AT+MODBUS=1. Communicate after connection is established The Modbus protocol of this module only supports data conversion and transmission. If necessary, please operate with the actual controls. Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 39: Static Ip Usage

    30 秒 sec (Tc) Average ramp-down rate (Tp~T 6℃/second max 6℃/second max Time 25℃ to peak temperature 6 minutes 8 minutes ※The peak temperature (Tp) tolerance definition of the temperature profile is the upper limit Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 40: Reflow Profile

    2020.12.03 Content changes 2021.04.09 product upgrade 1. Added English web page configuration interface. 2022.09.04 M.T. 2. Added the serial port wake-up function after hibernation. 2023.4.10 Add the welding operation instruction 2024.3.7 product upgrade Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 41: About Us

    E103-W06 User Manual About us Technical support: support@cdebyte.com Documents and RF Setting download link: https://www.ru-ebyte.com Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com ------------------------------------------------------------------------------------------------- Phone: +86 028-61399028 Web: https://www.ru-ebyte.com Address: B5 Mould Park, 199# Xiqu Ave, High-tech District, Sichuan, China...