  • Page 1 The Fredericks Company B2A Portable Thermocouple Controller Instruction Manual The Fredericks Company - Televac 2400 Philmont Avenue Huntingdon Valley, PA 19006 www.frederickscompany.com web: email: sales@frederickscompany.com tel: +1 215 947 2500 fax: +1 215 947 7464...
  • Page 2: Table Of Contents

    List of Figures B2A Portable Dimensional Drawing (inches) ......email: sales@frederickscompany.com tel: +1 215 947 2500 web: frederickscompany.com...
  • Page 3: Introduction

    The B2A Portable is a thermocouple vacuum sensor controller with a range of 1 Torr to 20 Torr. It utilizes a Televac thermocouple vacuum sensor, part number 2-2100-10 or 2-2126-0YY . It has an easy-to-read analog display that indicates pressure in units of mTorr.
  • Page 4: Safety Information

    START BY READING THESE IMPORTANT SAFETY INSTRUCTIONS AND NOTES In these instructions the word “product” refers to the B2A Portable and all of its approved parts and accessories. NOTE: These instructions do not and cannot provide for every contingency that may arise in connection with the installation, operation, or maintenance of this product.
  • Page 5: Dimensions

    1.5 Dimensions 1 INTRODUCTION 1.5 Dimensions Figure 1: B2A Portable Dimensional Drawing (inches) email: sales@frederickscompany.com tel: +1 215 947 2500 web: frederickscompany.com b2ap_im rev - 4 of 6...
  • Page 6: Setup

    B2A Portable cable until the correct alignment is obtained and the B2A Portable cable is able to slide onto the 2A sensor. Connect the RJ14 end of the B2A Portable cable into the port on the front of the B2A Portable. To take a reading using the B2A Portable, turn the left know on the front of the unit to the "READ"...
  • Page 7: Part Numbers

    3 PART NUMBERS 3 Part Numbers Table 2: Controller, Cable, and Sensor Part Numbers B2A Portable Controller 2-3001-100 2A Sensor 1/8” NPT Nickel-Plated Brass 2-2100-10 2A Sensor Stainless Steel 1/8” NPT 2-2126-001 2A Sensor Stainless Steel NW16 (DN16 ISO-KF) 2-2126-030...