Setup and Troubleshooting Guide for EthernetIP Option 2
Contents
1
Description....................................................................................................................................................... 1
2
Windows™ 7 Operating Systems Configuration ................................................................................................ 2
3
Windows™ 10 Operating Systems Configuration .............................................................................................. 7
4
Contact Us ..................................................................................................................................................... 12
1 Description
This document explains the process for the setup, configuration, and troubleshooting of a Televac EthernetIP device.
In order to communicate with the unit, the EthernetIP device's IP address will need to be configured to the same
network as the PLC. The following steps describe how to establish the initial connection, and what steps to follow
should any issues arise. The second setup option assumes no internet connectivity and explains how to reconfigure
the IP address of the local computer to match the module, which can then be connected to in order to adjust the
settings to the appropriate configuration. If an internet connection is available, refer to the Setup and
Troubleshooting Guide for Televac EthernetIP Option 1 (televac_an3017).
Please see the EthernetIP for MX200 User Manual for a full description on Class 1 and Class 3 connections, and a
complete ADI table including data instance, name, array length, access, and description. Please see Application
Note 3016 for downloading an Electronic Data Sheet (EDS) file to a PLC.
© 2017 The Fredericks Company | www.frederickscompany.com | sales@frederickscompany.com | +1 215 947 2500
Televac Application Note 3018
MX200 EthernetIP Vacuum Controller
1
Page
of
televac_an3018 rev -
12

Advertisement

loading

Summary of Contents for TELEVAC MX200

  • Page 1 Troubleshooting Guide for Televac EthernetIP Option 1 (televac_an3017). Please see the EthernetIP for MX200 User Manual for a full description on Class 1 and Class 3 connections, and a complete ADI table including data instance, name, array length, access, and description. Please see Application Note 3016 for downloading an Electronic Data Sheet (EDS) file to a PLC.
  • Page 2 2 Windows™ 7 Operating Systems Configuration Configuring the IP Address 2.1.1 Connect the MX200 EthernetIP port on the back of the unit to your computer. 2.1.2 Open the Network and Sharing Center in the Control Panel and verify that an Ethernet connection is being made.
  • Page 3 2.1.4 In the Local Area Connection Status panel, select Properties. 2.1.5 In the Local Area Connection Properties panel, select Internet Protocol Version 4 (TCP/IPv4) and select Properties. Page © 2017 The Fredericks Company | www.frederickscompany.com | sales@frederickscompany.com | +1 215 947 2500 televac_an3018 rev -...
  • Page 4 2.1.6 In the Internet Protocol Version 4 Properties panel, mark down the current settings to revert back to later. The local machine will need to be configured to the module to adjust the settings, but will need to be brought back onto the local network in order to communicate properly when finished. In this example, the local machine has an IPv4 address of 149.174.211.52 with a subnet mask of 255.255.0.0 and a default gateway of 149.174.211.2.
  • Page 5 2.1.8 The computer and unit should now be on the same local network. Open a browser, and enter the IP address of the unit (192.168.0.8) into the search bar. When prompted, enter the username and password (default Admin:admin). 2.1.9 The web page hosted by the module should appear. Select the Configuration tab on the left. 2.1.10 Change the IP address and subnet mask to the desired configuration (see step 2.1.6 for the network configuration).
  • Page 6 EthernetIP network settings. 2.2.3 The unit should now be ready to use with a PLC. Please refer to Televac Application Note 3016 for downloading the Electronic Data Sheet (EDS) and creating a connection.
  • Page 7 3 Windows™ 10 Operating Systems Configuration Configuring the IP Address 3.1.1 Connect the MX200 EthernetIP port on the back of the unit to your computer. 3.1.2 Open the Network and Sharing Center in the Control Panel and verify that an Ethernet connection is being made.
  • Page 8 3.1.4 In the Ethernet Status panel, select Properties. 3.1.5 In the Ethernet Properties panel, select Internet Protocol Version 4 (TCP/IPv4) and select Properties. Page © 2017 The Fredericks Company | www.frederickscompany.com | sales@frederickscompany.com | +1 215 947 2500 televac_an3018 rev -...
  • Page 9 3.1.6 In the Internet Protocol Version 4 Properties panel, mark down the current settings to revert back to later. The local machine will need to be configured to the module to adjust the settings, but will need to be brought back onto the local network in order to communicate properly when finished. In this example, the local machine has an IPv4 address of 149.174.211.116 with a subnet mask of 255.255.0.0 and a default gateway of 149.174.211.2.
  • Page 10 3.1.8 The computer and unit should now be on the same local network. Open a browser, and enter the IP address of the unit (192.168.0.8) into the search bar. When prompted, enter the username and password (default Admin:admin). 3.1.9 The web page hosted by the module should appear. Select the Configuration tab on the left. 3.1.10 Change the IP address and subnet mask to the desired configuration (see step 3.1.6 for the network configuration).
  • Page 11 EthernetIP network settings. 3.2.3 The unit should now be ready to use with a PLC. Please refer to Televac Application Note 3016 for downloading the Electronic Data Sheet (EDS) and creating a connection.
  • Page 12 4 Contact Us Please feel free to contact us with any questions: The Fredericks Company - Televac 2400 Philmont Avenue Huntingdon Valley, PA 19006, USA Web: www.frederickscompany.com Email: sales@frederickscompany.com Phone: +1 215 947 2500 Page © 2017 The Fredericks Company | www.frederickscompany.com | sales@frederickscompany.com | +1 215 947 2500...