Safety Information - Infinity BU-150 Service Manual

Powered subwoofer
Hide thumbs Also See for BU-150:
Table of Contents

Advertisement

Amplifier/Subwoofer
Warning
Any person performing service of this unit will be exposed to
hazardous voltages and the risk of electric shock.
assumed that any person who removes the amplifier from this
cabinet has
been properly trained in protecting against
avoidable injury and shock.
procedures are to be performed by qualified service personal
ONLY!
Caution
This unit does not have a power switch. Hazardous voltages
are present within the unit whenever it is plugged in.
Before the amplifier is plugged in, be sure its rated voltage
corresponds to the voltage of the AC power source to be
used. Incorrect voltage could cause damage to the amplifier
when the AC power cord is plugged in. Do not exceed rated
voltage by more than 10%: operation below 90% of rated
voltage will cause poor performance or may shut the unit off.
List of Safety Components Requiring
Exact Replacements
F1
Fuse SLO BLO 1.5A 250V 20mm.
UL approved
PWRCORD
SPT-2 or better with polarized plug, UL
approved wired with the hot side to fused side.
Use with factory replacement panel strain relief
only.
T1
Transformer. Use only factory replacement.
DBR
Bridge diode. Use only factory replacement.
C1, 2
2200uF, 100V electrolytic filter caps. Be sure
replacement part is at least the same working
voltage and capacitance rating. Also the lead
spacing is important. Incorrect spacing may
cause premature failure due to internal cabinet
pressure and vibration.
C6
4.7uF 100V electrolytic radial
S64AMI
Power output module. Use only factory
replacement
Faceplate
Faceplate. Use only factory replacement
Air leak cover Use only factory replacement
CMC1
Use only factory replacement
L1
Use only factory replacement
Fuse PCB
Use only factory replacement
Main PCB
Use only factory replacement

SAFETY INFORMATION

It is
Therefore, any service
Leakage/Resistance Check
Before returning the unit to the customer, perform a leakage
or resistance test as follows:
Leakage Current. Note there is no power switch on this unit.
When the power plug is plugged in, the unit is live. Connect
the unit to its rated power source. Using an ammeter,
measure the current between the neutral side of the AC
supply and chassis ground of the unit under test. if leakage
current exceeds 0.5mA, the unit is defective. Reverse the
polarity of the AC supply and repeat.
Resistance. Measure the resistance from either side of the
line cord to chassis ground. If it is less than 500k ohms, the
unit is defective.
WARNING! DO NOT return the unit to the customer if it fails
one of these tests until the problem is located and corrected.