Hook-To-Needle Clearance, Needle Bar Rise, Needle Height And Needle Guard - Pfaff 333-712/02 Adjustment Manual

Hide thumbs Also See for 333-712/02:
Table of Contents

Advertisement

Adjustment
13

Hook-to-needle clearance, needle bar rise, needle height and needle guard

.04.03
O Loosen screws 1 and 2 (screw 2 is located on the back of the machine).
O Move the needle bar to b.d.c. and slide the 1.8 mm thick feeler gauge with its cutout
O Remove the feeler gauge and turn the handwheel in the direction of rotation until the
O Adjust the hook on the hook shaft according to rule 1
O Turn the hook according to rule 2 (readjust the needle height if necessary), see chapter
O Move the hook shaft bearing 3 until it abuts the hook and tighten the screw 2.
O Move the bevel gear 4 until it abuts the bearing 5 and tighten the screws 1.
8
Rule
With the needle rise positioned 1.8 mm after b.d.c. of the needle bar:
1. the hook point should be at the needle midpoint and have a clearance of 0.05 to
0.1 mm to the needle.
2. the upper edge of the eye of the needle should be 0.8 mm under the tip of the hook.
1
1
Fig. 13 - 03
tightly under the lower needle bar bearing. Move the screw clamp so that it touches the
feeler gauge and tighten it.
screw clamp rests on the needle bar bearing
13.04.02 Needle height (pre-calibrating).
The setting of the end play of the hook shaft and hook shaft bearing 3 is
omitted in machines with thread trimmer -900/51.
3
2
0.05 - 0.1 mm
4
5

Advertisement

Table of Contents
loading

Table of Contents