Needle Height (Pre-Calibrating) - Pfaff 333-712/02 Adjustment Manual

Hide thumbs Also See for 333-712/02:
Table of Contents

Advertisement

13
Needle height
.04.02
Rule
When the needle bar is in b.d.c., the clearance between the needle bar and stitch platen
should be 23 mm.
Fig. 13 - 02
O Adjust the needle bar 1 (screw 2) without twisting according to the rule.
(pre-calibrating)
Adjustment
2
1
7