Otherwise); Troubleshooting (To Be Performed By Trained Service Providers Only) - Oasis FSC463R Installation & Operating Manual

Refrigerated grab-n-go merchandiser
Hide thumbs Also See for FSC463R:
Table of Contents

Advertisement

TROUBLESHOOTING (TO BE PERFORMED BY STORE PERSONNEL UNLESS STATED OTHERWISE)
CONDITION
Water Is On The Floor
Fans Emit Excessive Noise
No Case Lights Are
Working
One (or Several) Case
Lights are Not Working
Case is Not Holding Proper
Temperature
Floor drain units: Check that drain (at underside of case) is properly routed
to floor drain.
Call service provider.
Call service provider.
Check that light switch is in the on position.
Check that ALL of the light cords and plugs are properly connected. See
MAINTENANCE FUNDAMENTALS - SHELF & BRACKET ASSEMBLY
REMOVAL / LIGHT FIXTURES section in this manual for specifics.
Authorized Service Contractors Only:
tripped circuit.
If case lights still do not come on, call service provider.
Check that ALL of the light cords and plugs are properly connected. This
includes the following items:
Oval form of plug must connect to oval form of LED light.
The power end of cord is to connect at the "red dot" marker at the end
of the LED lamp.
See MAINTENANCE FUNDAMENTALS - SHELF & BRACKET
ASSEMBLY REMOVAL / LIGHT FIXTURES section in this manual
for more specifics including illustrations.
If case light still do not come on, call service provider.
If a large amount of warm product was added to the case, it will take time
for the temperature to adjust. Product must be pre-chilled before placing
in case.
Check that the case is not in the sun or near a heat or air-conditioning
vent. See OVERVIEW / TYPE / COMPLIANCE / WARNINGS /
PRECAUTIONS / WIRING DIAGRAM section in this manual for
specifics.
If case is located near front doors, temperature fluctuation can hinder
unit's ability to maintain temperature. See OVERVIEW / TYPE /
COMPLIANCE / WARNINGS / PRECAUTIONS / WIRING DIAGRAM
section in this manual for specifics.
Check air return grilles (area at front of decking) for obstructions.
DO NOT set product on air grilles as this will prevent proper airflow!
If case still is not holding proper temperature, call service provider.
18
TROUBLESHOOTING
Check circuit breaker box for

Advertisement

Table of Contents
loading

Table of Contents