Advertisement

Quick Links

2TMD041800D0018
20.06.2019
Product manual
ABB-Welcome IP
H8303 Guard unit
H8303-02 Guard unit

Advertisement

Table of Contents
loading

Summary of Contents for ABB H8303

  • Page 1 │ 2TMD041800D0018 20.06.2019 Product manual ABB-Welcome IP H8303 Guard unit H8303-02 Guard unit...
  • Page 2: Table Of Contents

    Table of contents Notes on the instruction manual ........................4 Safety ................................4 Intended use ..............................4 Environment ..............................5 ABB devices ............................5 Product description ............................6 Control elements ..........................6 Terminal description ........................... 7 Technical data ............................... 8 Mounting/Installation ............................
  • Page 3 Table of contents Call forwarding ..........................39 Emergency unlock ..........................40 Lock group ............................43 Alarm record ............................. 45 FCC ................................47 Cyber security .............................. 48 11.1 Disclaimer ............................48 11.2 Performance and service ......................... 48 11.3 Deployment guideline ........................49 11.4 Upgrading ............................
  • Page 4: Notes On The Instruction Manual

    Please keep this manual in a safe place. If you pass the device on, also pass on this manual along with it. ABB accepts no liability for any failure to observe the instructions in this manual. Safety...
  • Page 5: Environment

    ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal. Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company.
  • Page 6: Product Description

    Product description Product description Control elements Function Handset Touch screen │6 Product manual 2TMD041800D0018...
  • Page 7: Terminal Description

    Product description Terminal description Function Power input connector Power input connector (DC-JACK input) Fire control input (release all the locks in case of emergency) LAN (PoE) Microphone Speaker │7 Product manual 2TMD041800D0018...
  • Page 8: Technical Data

    Technical data Technical data Designation Value Rating voltage 24 V DC Operating voltage range 20-27 V DC 27 V DC, 230 mA Rating current 24 V DC, 260 mA Display size 7" Resolution 1024 x 600 pixel Product dimensions 265 mm × 165 mm × 115 mm Operating temperature -10 °C…+55 °C PoE standard...
  • Page 9: Mounting/Installation

    Mounting/Installation Mounting/Installation Warning Electric voltage! Dangerous currents flow through the body when coming into direct or indirect contact with live components. This can result in electric shock, burns or even death. – Disconnect the mains power supply prior to installation and/or disassembly! –...
  • Page 10: Mounting

    Mounting/Installation Mounting │10 Product manual 2TMD041800D0018...
  • Page 11: Commissioning

    Commissioning Commissioning Initial setup The guard unit enters initial setup automatically when powered on the first time or when "Clear all data" is carried out on the "Engineering settings" screen. Please see the "Local settings" chapter for more details. 1. Select system language │11 Product manual 2TMD041800D0018...
  • Page 12 Commissioning 2. Accept licensing terms │12 Product manual 2TMD041800D0018...
  • Page 13 Commissioning 3. Set date and time │13 Product manual 2TMD041800D0018...
  • Page 14: Enter System Settings

    Commissioning Enter System settings On the extra screen, click "System" to access the corresponding screen. │14 Product manual 2TMD041800D0018...
  • Page 15: Sound Settings

    Commissioning Sound settings On the "System settings" screen, click "Sound" to access the settings. Function Touch sound setting Ringtone setting Click the drop-down list to select the ringtones for outdoor stations, indoor stations, guard unit (4 bulit-in ringtones). Volume settings Adjust the ringtone volume.
  • Page 16: Language Settings

    Commissioning Language settings On "System settings" screen, click "Language" and select the system language. │16 Product manual 2TMD041800D0018...
  • Page 17: Display Settings

    Commissioning Display settings On the "System settings" screen, click "Display" to access the corresponding screen. Function Clear screen ■ The countdown (1…30) is displayed on the screen if this function is activated. Any actions on the screen will be invalid. ■...
  • Page 18: Date And Time Settings

    Commissioning Date and time settings On the "System settings" screen, click "Date and time" to access the corresponding screen. Function Sync time type Tick the checkbox to sync the date and time from the management software automatically. Time and date setting Summer time Tick the checkbox to enable the function.
  • Page 19: Monitor Settings

    Commissioning Monitor settings On the "System settings" screen, click "Monitor settings", and then click "Download the camera list" to download the camera list from the management software. │19 Product manual 2TMD041800D0018...
  • Page 20: Engineering Settings

    Commissioning Engineering settings 8.8.1 Enter engineering settings On the "System settings" screen, click "Engineering settings", enter the engineering password to access the settings. Password rule The user must change the engineering password when accessing the engineering settings for the first time. This engineering password must not include increasing or decreasing numbers (e.g.
  • Page 21: Local Settings

    Commissioning 8.8.2 Local settings Function Device No Range is 1...32. Call mode Toggles the call mode between "Physical address" (default) and "Logical address". The 2nd lock Releases the secondary lock on the outdoor station if the function is enabled. Security mode/Compatible mode The guard unit works in "Security mode"...
  • Page 22: Change Password

    Commissioning 8.8.3 Change password On the "System settings" screen, click "Password management" to access the settings. Function Change engineering password Click here to change the engineering password (the system default is 345678). Change lock group password Click here to change the lock group password (the system default is 123456). Please see the "Lock group"...
  • Page 23: Lock Group

    Commissioning 8.8.4 Lock group This function is only available on the guard unit which is set to "Security mode". On the "Engineering settings" screen, click "Lock management" and "Add area" to access the settings. Tick the "Lock group" checkbox to enable the function, select the lock, enter the area name (e.g. "E01") and click "OK"...
  • Page 24: Emergency Unlock

    Commissioning 8.8.5 Emergency unlock On the "Engineering settings" screen, click "Lock management", then click "Add area" to access the settings. Tick the check box "Emergency" to enable the function, select the lock, enter the area name (e.g. "All") and click "OK" to save. │24 Product manual 2TMD041800D0018...
  • Page 25 Commissioning Fire linkage This function is only available on the guard unit which is set to "Security mode". On the "Engineering settings" screen, click "Lock management", tick the "Fire linkage" checkbox to enable the function (the system default is disabled). Select lock open type (e.g.
  • Page 26: Reset Settings

    Commissioning Reset settings On the "System settings" screen, click "Reset user settings", enter the user password (the system default is 123456) and click "OK" to reset the user settings. │26 Product manual 2TMD041800D0018...
  • Page 27: About

    Commissioning 8.10 About On the "System settings" screen, click "About" to view the version information. Function Version information Address of the guard unit Serial number This number is used to obtain the certificate from the management software. Signature This number is displayed when the guard unit receives the certificate from the management software successfully.
  • Page 28: Add A Contact

    Commissioning 8.11 Add a contact On the DES home screen, click to access the corresponding screen. On the "Intercom contacts" screen, click to access the settings. Click "Add contacts" to add a contact. Click "Download contacts" to download the contacts from the management software. Click "Delete All"...
  • Page 29: Operation

    Operation Operation Incoming call 9.1.1 Call from outdoor station/gate station The guard unit displays the image as full screen by default. Click to switch to normal screen mode. Function Caller ID Display the image of the outdoor stations (the countdown will be displayed in the last 9 s). Click this icon to accept the call.
  • Page 30: Calling From The Guard Unit/Indoor Station

    Operation 9.1.2 Calling from the guard unit/indoor station Function Caller ID Display the countdown in the last 9 s. Click this icon to accept the incoming call. Click this icon to mute the ringtone on this device. Click this icon to end the call. Click this icon to mute the volume.
  • Page 31: Intercom

    Operation Intercom 9.2.1 Accessing the intercom screen In standby mode, click on the DES home screen to access the corresponding screen. │31 Product manual 2TMD041800D0018...
  • Page 32: Initiating An Intercom Call

    Operation 9.2.2 Initiating an intercom call On the Intercom screen, select a contact, then click to initiate an intercom call You can also click and enter the physical address/logic address, click to initiate an intercom call. │32 Product manual 2TMD041800D0018...
  • Page 33: Surveillance

    Operation Surveillance In standby mode, on the DES screen, click to start a surveillance. │33 Product manual 2TMD041800D0018...
  • Page 34: Surveillance From Outdoor Station/Gate Station

    Operation 9.3.1 Surveillance from outdoor station/gate station Function Caller ID Display the image from the outdoor station. (the countdown will be displayed in the last 9 s) End the surveillance. Release the default lock Click this icon to release the default lock of the monitored outdoor station. Release the 2nd lock Click this icon to release the secondary lock of the monitored outdoor station.
  • Page 35: Calling Other Guard Unit

    Operation 9.3.2 Calling other guard unit In standby mode, click on the DES home screen to enter corresponding screen. Click and entert "#"+ "Guard unit no.", then click to initiate an intercom call. │35 Product manual 2TMD041800D0018...
  • Page 36: History

    Operation History In standby mode, click on the DES home screen or click on the status bar to access the "History" screen. │36 Product manual 2TMD041800D0018...
  • Page 37 Operation A maximum of 30 call records can be stored. Highlighting indicates unread status. Click the picture to see details on the pop up window. Click "<" or ">" to view the pictures. (a maximum of 3 pictures for each record) │37 Product manual 2TMD041800D0018...
  • Page 38 Operation Click to enter the settings. Click "Delete All" to delete the entire history record. │38 Product manual 2TMD041800D0018...
  • Page 39: Call Forwarding

    Operation Call forwarding When the guard unit receives a call from an outdoor station, you can click to access "Call forward" screen, then click to transfer the call to the indoor station. Or you can click then enter the address of the indoor station to transfer the call. │39 Product manual 2TMD041800D0018...
  • Page 40: Emergency Unlock

    Operation Emergency unlock On the extra screen, click "Emergency unlock" to access the corresponding screen. │40 Product manual 2TMD041800D0018...
  • Page 41 Operation Click , then enter the emengency unlock password (the system default is 123456), click "OK" to unlock. will be displayed if successful. If you want to lock again, you can click , then enter the emengency unlock password, click "OK"...
  • Page 42 Operation Fire alarm If the "Fire linkage" function is used and related to the emergency unlock or lock group, when the alarm is triggered, the guard unit may receive the the message below. │42 Product manual 2TMD041800D0018...
  • Page 43: Lock Group

    Operation Lock group On the extra screen, click "Lock group" to access the corresponding screen. │43 Product manual 2TMD041800D0018...
  • Page 44 Operation Click , then enter the lock group passward (the system default is 123456), click "OK" to unlock. will be displayed if successful. If you want to lock it again, you can click , then enter the lock group password and click "OK"...
  • Page 45: Alarm Record

    Operation Alarm record On the extra screen, Click "Alarm record" to access the corresponding screen. A maximum of 100 alarm records is supported. The guard unit will display the alarm message and paly the alarm sound if there is an alarm (e.g. SOS, zone alarm, duress alarm, tamper alarm) is sent from the indoor station or the outdoor station.
  • Page 46 Operation │46 Product manual 2TMD041800D0018...
  • Page 47: Fcc

    This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Only operate the device in accordance with the instructions supplied.
  • Page 48: Cyber Security

    11.1 Disclaimer H8303 product is designed to be connected and to communicate information and data via a network interface, which should be connected to a secure network. It is customer‘s sole responsibility to provide and continuously ensure a secure connection between the product and customer‘s network or any other network (as the case may be) and to establish and maintain...
  • Page 49: Deployment Guideline

    11.6 Malware prevention solution The device H8303 is not susceptible to malware, because custom code cannot be executed on the system. The only way to update the software is by firmware upgrading. Only firmware signed by ABB can be accepted.
  • Page 50 We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice. The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no responsibility for possible errors or incompleteness in this document.
  • Page 51 Km 9 National Highway 1A , The detailed specifications agreed P.O.Box 11070 Dubai-UAE Hoang Liet, Hoang Mai, Hanoi, upon apply for orders. ABB accepts T : +971 4 3147 586 Vietnam no responsibility for possible errors F : +971 4 3401 541 T : +84 4 3861 1010 or incompleteness in this document.
  • Page 52 Error! Use the Home tab to apply Überschrift 1 to the text that you want to appear here. Copyright 2019 ABB © All rights reserved │52 Product manual 2TMD041800D0018...

This manual is also suitable for:

H8303-02

Table of Contents