Necessary Tools for Installation
Driver
Nipper
Hacksaw
Hole core drill
S panner(17,19 and 26mm)
G as leak age detector or
soap-and-water solution

Selection of the Installation Location

RISK OF PERSONAL INJURY.
Do not locate the Indoor Unit in a location where the
airflow is likely to be channeled directly at people or
animals.
Install on the wall that is sufficiently strong and robust
to support the weight of the Indoor unit.
T he installation location should be away from sources
of heat and humidity.
Locate where the connection piping& electrical cable
can be easily connected to the outdoor unit.
Locat e where the drain house outlet will not cause a
disturbance on the outside of the wall.
Locate where the cooled/heated air can be spread entirely
around the room ( avoid corners of rooms) .
Locat e clos e to an accessible power outlet.
Locate more than 1m away from televisions, wireless devices
and fluoresecent lamps.
If the remote control is fixed to a wall, locate it in a location
where the signal is not affected by fluorescent light starting
devices.
T hese indoor unit models are designed exclusively for use with HF C refrigerant R 410A .
more than 15 cm
more than
10cm
T he distance between the indoor unit and the floor should be more than 2m.
Please be subject to the actual product purchased,the above picture is just for your reference.

Indoor Unit Installation

Torque wrench
(17mm, 22mm, 26mm)
P ipe cutter
F laring tool
K nife
Measu ring tape
Reame r
Drawing for the installation of indoor units
Risk of electric shock. Can cause injury or death.
T he electrical power outlet should be located sufficiently close
to the indoor unit, such that the cord-set and plug are not placed
under strain.
Do NO T extend the power cord for any reason. If the electrical
power outlet is too far away, it should be relocated by a qualified
electrician in accordance with local codes and regulations.
T he air conditioner should always be plugged into itsown
individual electrical outlet having a voltage rating that matches
the rating plate.
T he electrical power outlet should have sufficient capacity for the
rated input current/power marked on the rating plate.
A exclusive brance circuit should be used.
Remot e controlle r (1)
Air purifying filter((1)
Mounting plate (1)
FOR 09K 12K
FOR 18K
24K
Attention must be paid to
the rising up of drain hose
more than 10cm
11

Power Source

Accessory Parts

Drain hose (1)
P lastic cap (4)
Ø 4X 25 S crew (4)
Ø 4X 12 S crew (2)
Selection of Pipe
A rrange ment of piping
directions
Rea r left
Le ft
Below
Rear
right
R ight