3.6 Illustrated description

1
Fuel cap
2
Fuel level indicator
3
Remote starter
4
Control panel
5
Starting grip
6
Command the fuel shutoff valve
7
Maintenance cover
8
AC socket
9
Overload indicator light
10 Output indicator available
11 Oil alert indicator light
12 ON/OFF Switch
13 Switch economizer
14 Electrical Grounding
15 Out of 12 Vdc
16 Automatic output Protector
17 Oil drain plug
18 Oil filler cap
19 Fuel primer bulb
20 Overload Protector 12V

3.7 Limitations of environmental conditions

Apply regard contained in Chapter 2 "specific safety
instructions."

4. Operating instructions

4.1 Placement and testing

Be sure to check the generator on a level surface
with the engine stopped.
4.2 Start 4T (except GID 1000)
Before starting the engine, disconnect any load
from the receptacle.
Set the fuel valve in the "ON"-position.
To start a cold motor shove the choke lever all the way to the
left. To restart a hot motor set the choke lever half-way.
Shove the choke to about halfway to restart a warm motor.
A hot motor will not start if there is too much fuel
in the cylinder.
If this happens, wait five to ten minutes before
trying again. Shove the choke completely to the
right and the motor should start.
Set the motor switch 12 in the "ON"-position.
Pull slightly on the start cord 5 until you feel resistance and
then yank hard and swiftly.
Do not let the start cord retract by itself: guide it
back by hand. Hold the carrying handle firmly to
prevent the generator from falling over when you
pull the start cord.
Press the choke in completely after the engine is started.
ENGLISH
10
Economizer button will fuel saving mode 12V max supply.
Never start with the economizer.
If the engine stops and will not restart, check the
engine oil level before troubleshooting in other
areas.
Start GID1000 (2T)
GID1000 model has a 2-stroke engine.
GAV2800 and GAV5500E models have a 4-stroke engine.
Turn the fuel valve ON.
To boot, full choke left the starter 3. Pull the lever 5 until you
hear the first detonations.
Then put the starter 3 in medium or low position and pull the
starter definitive.

4.3 System Low oil warning

Models GID1400 / GID2200: The oil alert system 11 is
designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil
level in the crankcase falls below a safe limit, the oil alert
system will automatically shut down the engine (the engine
switch will remain in the ON position).
If the oil alert system shuts down the engine, the oil alert
indicator light (red) will come on when you operate the
starter, and the engine will not run. If this occurs, add engine
oil. The other models have no explicit warning of low oil.
However not start if the oil level is low.

4.4 AUX output 12V

The 12 Vdc auxiliary connection can be used while using
the AC output.
A GID1000 DC overload, and GID 2200 GID1400
disconnect the DC circuit protector 20. If this happens,
unplug the DC load before resetting the circuit protector to
resume operation.

4.5 Overload

The team cut the electricity supply if a consumer exceeds
the maximum, to restore supply shut off the engine and
start it again in the models GID (Inverter). In AVR
moldelos reset the circuit breaker 16.

4.6 Stopping the engine

To stop the engine in an emergency, turn the engine switch
12 to the OFF position.
In normal use:
Switch off the connected equipment and pull the inserted
plug out.
Turn the engine switch 12 to the OFF position.
Turn the cap lever fully counter clockwise to the "OFF"
position.
Be sure both the fuel cap lever and the engine
switch are in "OFF" position when stopping,
transporting and/or storing the generator.