For Your Safety - Fein MBS16X Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
OBJ_BUCH-0000000161-001.book Page 22 Tuesday, March 11, 2014 7:56 AM
en
22

For your safety.

Intended use of the magnetic drill stand:
Magnetic drill stand for holding a drive motor, for drilling
with solid drill bits, reaming and tapping on materials with
surfaces suitable for magnets in weather-protected envi-
ronments using the application tools and accessories rec-
ommended by FEIN.
Intended use of the industrial drill stand:
Industrial drill stand for holding a drive motor, for drilling
with solid drill bits, reaming and tapping on materials with
surfaces suitable for magnets in weather-protected envi-
ronments using the application tools and accessories rec-
ommended by FEIN.
General safety instructions for drill stands.
Read all safety warnings and all
WARNING
instructions provided with the mag-
netic drill stand/industrial drill stand or the power tool.
Failure to follow the warnings and instructions may result
in electric shock, fire and/or serious injury.
Save all safety warnings and instructions for future ref-
erence.
The term "power tool" used in the safety instructions,
refers to mains-powered power tools (with mains cable)
and to battery-operated power tools (without mains
cable).
Pull the plug from the mains receptacle and/or remove
the battery before making adjustments on the tool or
changing tool accessories. Unintentional switching on of
the power tool is the cause of many accidents.
Before mounting the power tool, install the magnetic drill
stand/industrial drill stand correctly. The correct installa-
tion is important in order to prevent the risk of the drill
stand folding together.
Attach the power tool securely to the magnetic drill
stand/industrial drill stand before using it. Slipping off of
the power tool on the magnetic drill stand/industrial drill
stand can lead to loss of control.
Place the drill stand on a firm, level and horizontal sur-
face. If the drill stand can slip off or wobble, the power
tool cannot be uniformly and securely guided.
Do not overload the magnetic drill stand/industrial drill
stand and do not use it as a ladder or scaffolding. Over-
loading or standing on the magnetic drill stand/industrial
drill stand can lead to the upward shifting of the centre of
gravity of the magnetic drill stand/industrial drill stand and
its tipping over.
Please also observe the relevant national industrial
safety regulations.
Special safety instructions.
Wear personal protective equipment. Depending on appli-
cation, use face shield, safety goggles or safety glasses.
Where appropriate, wear dust mask, hearing protectors,
gloves and workshop apron capable of stopping small
abrasive or workpiece fragments. The eye protection
must be capable of stopping flying debris generated by
various operations. The dust mask or respirator must be
capable of filtrating particles generated by your opera-
tion. Prolonged exposure to high intensity noise may
cause hearing loss.
When there is danger of falling down, secure the mag-
netic drill stand using the provided lashing strap; espe-
cially when working aloft, on vertical building elements
or overhead. In case of a power failure or when the mains
plug is pulled, the magnetic holding power is not main-
tained.
When working overhead or on vertical surfaces, the cool-
ant container must not be used. Use a coolant spray
instead. Liquids penetrating your electric power tool may
cause electric shock.
Operate the magnetic drill stand only from socket outlets
with the earthing contact according to regulations. Only
use undamaged supply cords and regularly checked
extension cords with earthing contact. A protective con-
ductor without continuity can lead to electric shock.
Do not direct the power tool against yourself, other per-
sons or animals. Danger of injury from sharp or hot
application tools.
Do not rivet or screw any name-plates or signs to the
magnetic drill stand/industrial drill stand. If the insulation
is damaged, protection against an electric shock will be
ineffective. Adhesive labels are recommended.
Do not use accessories not specifically developed or
released by the manufacturer for the magnetic drill
stand/industrial drill stand. Safe operation is not ensured
only because an accessory fits your magnetic drill stand/
industrial drill stand.
Clean the ventilation openings on the power tool at regu-
lar intervals using non-metal tools. The blower of the
motor draws dust into the housing. An excessive accu-
mulation of metallic dust can cause an electrical hazard.
Before putting into operation, check the mains connec-
tion and the mains plug for damage.
Recommendation: The tool should always be supplied
with power via a residual current device (RCD) with a
rated current of 30 mA or less.
Operating Instructions.
When a power tool is mounted that is
WARNING
not intended for use with the mag-
netic drill stand/industrial drill stand, the magnetic drill
stand/industrial drill stand can tip over.
Only use non-water mixable coolants or oil as the cool-
ing agent.
Use the magnetic drill stand/industrial drill stand suitable
for the performance characteristics of your drive motor.
Pay attention that the set-up surface for the magnetic foot
of the magnetic drill stand is flat, clean and rust-free.
Remove varnish and putty/filler layers.