Air Filter with Automatic Drain
Part No. 22601, Series B
Maintenance
To maintain maximum filtering efficiency and to
avoid excessive pressure drop, the filter must be
kept clean. Bowl drainage is automatic with the
float drain. Remove the bowl to drain manually. A
visible coating of dirt on the filter element surface or
an excessive pressure drop is an indication that
cleaning is necessary.
Cleaning
To clean, it is not necessary to remove the com-
plete filter from the line. Disassembly is simple and
does not require tools. Before disassembly, shut off
the air supply and depressurize filter. Clean all
parts with cleaning solvent and blow out filter body
before reassembly. Wash filter element in cleaning
solvent and blow out from the inside.
Automatic Drain
The Automatic drain is equipped with a float actu-
ated device which automatically ejects liquid con-
taminates under pressure.
Specifications
Air Inlet 1/2 in. F.P.T.
Air Outlet 1/2 in. F.P.T.
Air Flow Capacity 100 cfm (3.2 m
(0.7 MPa, 7 bar)
Max. Operating Pressure 175 psi (1.2 MPa, 12 bar)
Max. Temperature 150°F (65°C)
Parts (Series B)
Part No.
Description
24U115
Automatic Drain
127289
O-Ring
16W811
Baffle End Cap
16W405
Filter Element
Filter Element
(16W405)
Baffle End Cap
3
(16W811)
/min.) at 100 psi
Important Safety Instructions
Read all warnings and instructions in your
equipment manual. Save all instructions.
Automatic
Drain
(24U115)
310611G
EN
O-Ring
(127289)
ti22164a

Advertisement

loading

Summary of Contents for Graco Sharpe B Series

  • Page 1 Instructions/Parts In-Line Filters and Coalescers 310611G with Automatic Drains Air Filter with Automatic Drain Important Safety Instructions Part No. 22601, Series B Read all warnings and instructions in your equipment manual. Save all instructions. Maintenance To maintain maximum filtering efficiency and to avoid excessive pressure drop, the filter must be kept clean.
  • Page 2 Coalescer with Automatic Drain Coalescer with Automatic Drain Installation It is always recommended that a Sharpe air filter be (Part No. 22605, Series B) installed upstream of the coalescing filter to remove 0.01 micron and larger size particles and separate large droplets of moisture from the air line.
  • Page 3 Model 707F 3/4 in. In-Line Filter with Automatic Drain Model 707F 3/4 in. In-Line Filter with Automatic Drain (Part No. 6920) • Removes all liquids (oil and water) • Filters Particulate down to 5 microns • Features large REUSABLE filter element •...
  • Page 4 Self-Relieving Air Regulator (Part No. 22604) Self-Relieving Air Regulator AIR REGULATOR (Part No. 22604) (22604) AIR PRESSURE GAUGE (8230) 22682 PLUG (10028) NIPPLE OUTLET (22687) VALVE (34700) Specifications Air Inlet 3/8 in. F.P.T. Air Outlet 1/4 in. F.P.T. (3 EA.) Air Flow Capacity 100 cfm (2.8 m /min.) Max.
  • Page 5 Self-Relieving Air Regulator (Part No. 22604) 310611G...
  • Page 6: Year Limited Warranty

    All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. Original instructions. This manual contains English. MM 310611 SHARPE MANUFACTURING •...

This manual is also suitable for:

Sharpe 22601Sharpe 707fSharpe 707cSharpe 22605Sharpe 707fcSharpe 22604 ... Show all