AMC MUX and AMC MUX-EXT
4.2

Features

4.3

Applications

You can install the AMC MUX module in different places in the
system. One option is to convert the COM interface of the PC
into RS-485/RS-422 (Figure 4.4).
Fig. 4.4 Convertion RS-232 to RS-485/RS-422
In Figure 4.4, one device is connected. By using a bus protocol,
you can connect more then one device - up to eight (Figure 4.5).
Bosch Security Systems
There are three configurable operation modes:
RS-232
RS-232
RS-232
Data rates: 9.6 / 19,2 / 38,4 / 57,6 or 115,2kbps
Self-controlling transmission/reception switch
Electrical isolation between RS-232 and RS-485/RS-422
Input power from 10V DC to 30V DC
Low power consumption
DIN rail mountable
Connect up to eight RS-485 interfaces using AMC MUX-EXT
expansion modules. Star wiring up to 1200m (4000ft)
cable length is acceptable.
Installation manual
RS-485 2-wire
RS-485 4-wire
RS-422
Functional Description | en 17