Dyna-Glo DGP321SNN Manual page 25

2 burner premier natural gas grill
Table of Contents

Advertisement

Available languages

Available languages

TROUBLESHOOTING
PROBLEM
The burner will not
light with a match
No gas flow or an
obstructed gas flow
POSSIBLE CAUSE
1. Match not reaching burners
(when holding match with hand).
2. Gas supply shut off.
3. Poor connection between gas
hose plug fitting and sleeve
coupling.
4. Burner inlet blocked.
1. Gas supply shut off.
2. Poor connection between gas
hose plug fitting and sleeve
coupling.
3. Burner inlet blocked.
CORRECTIVE ACTION
1. Use match holder found in
cabinet door.
2. Check that the natural gas supply
shut-off valve is open.
3. Turn off the grill knobs, close the
gas supply shut-off valve and
check the connection between
the plug and sleeve coupling.
Disconnect and reconnect, if
necessary.
4. Clean the burner inlet (venturi) and
burner as described by the Care
and Maintenance section in the
manual.
1. Check that the natural gas supply
shut-off valve is open.
2. Turn off the grill knobs, close the
gas supply shut-off valve and
check the connection between
the plug and sleeve coupling.
Disconnect and reconnect, if
necessary.
3. Clean the burner inlet (venturi) and
burner as described by the Care
and Maintenance section in the
manual.
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents