UBS Hydro II
Operation
2018-05-02
Fig. 10: Operating Unit
1
Drive lever
2
Drive lever
3
Ignition key
4
Auxiliary drive
5
Gas handle
6
Engine switch
To switch off the engine, carry out the following steps:
Before switching off the engine, make sure that the drive levers (1 and 2) are
in horizontal position and the lever of the auxiliary drive (4) is in its "Off"
position.
Put the gas handle (5) in neutral position and leave the engine running at
idle for approx. half a minute.
Set the engine switch (6) on the engine in its „O" position.
Close the fuel valve
Secure the one-axle tractor against unauthorised usage and pull out the
ignition key (3) if necessary.
When leaving the machine, secure it against rolling away by placing wheel
chocks or, if necessary, by activating the locking brake.
For longer standstill periods of the engine, do not switch off the "Engine-Off switch"
but close the fuel valve and leave the engine running until it automatically comes to
a standstill. With this, the gasifier is empty and it cannot become resinous.