3.1.4 typical through the wall

If possible, design the installation so that the connector does not pass through a combustible wall. If during
your installation you must pass through a combustible wall, check with your building inspector before you
begin. Also check with the chimney connector manufacturer for any specific requirements.
Consult with your dealer regarding special connection components available for use for wall pass-throughs.
Use only parts that have been tested and listed for use in a wall pass-through.
MAINTAIN 2"
TERMINAL
ROOF
(50.8mm) CLEARANCE
THROUGH EAVE
STORM
COMBUSTIBLE
COLLAR
OUTSIDE WALL
LISTED
FLASHING
SECTION
CHIMNEY
LISTED
2" (50.8mm)
CHIMNEY PIPE
CLEARANCE
TO
INSULATED
STOVE
"T"
COMBUSTIBLE
CEILING
WALL
SUPPORT
THIMBLE
WALL SPACER
FOR OUTSIDE
WALL
CHIMNEY
CONNECTOR
COMBUSTIBLE
FLOOR
WALL
PROTECTOR