2048 pixels, 14 µm x 14 µm, 15 MHz pixel frequency
Camera
Sensor
Type
Pixel number
Pixel size
Pixel spacing
Sensor width
Active length
Anti-Blooming
Integration Control
Shading Correction
Window Function (ROI)
Pixel frequency
Line frequency max
Line frequency min
Integration time max
Integration time min
Dynamic range
Spectral range
Video signal
Interface
Voltage
Power consumption
Casing (W x H x D)
Objective mount
Weight
Working temperature
1)
Longer exposure times are possible in trigger mode "exposure active".
Contents
Section
1.
Introducing the SK2048USD Camera
2.
3.
4.
Line scan cameras from Schäfter+Kirchhoff are supplied factory-preset for the particular application. If you are not familiar with line scan
cameras, or their operation using the supplied software, then consult the glossary in Section 7. Line Scan Camera Fundamentals, p 10.
Kieler Str. 212, 22525 Hamburg, Germany
SK2048USD
Single Line Sensor
IL-P3-B
2048
14 µm x 14 µm
14 µm
14 µm
28.7 mm
yes
yes
no
yes
15 MHz
0.03 kHz
35 ms
1)
2 µs
1:2500 (rms)
400 - 900 nm
monochrome 8/12-bit digital
Interface:
USB 2.0
+5 V (300 mA)
1.6 W
AU2 (65 x 65 x 73 mm)
M40 x 0.75
0.2 kg
+5°C to +45°C
Page Section
Tel: +49 40 85 39 97-0
1
Monochrome line scan camera
1
SK2048USD
with
2
3
4
Photo lens Nikon AF 1:1.4/f'=50 mm,
M40x0.75 thread, with locking bridge
for fixing focus and aperture
4.4 Anti-blooming Adjustment
2
2
5.
Sensor Performance Specifications
6.
3
4
7.
4
8.
9.
4
4
Fax: +49 40 85 39 97-79
info@SuKHamburg.de
• Robust input and
output connections
• Hot-pluggable
• Ultimate in mobility
Interface:
USB 2.0
2
3
4
Interface:
USB 2.0
Page
5
6
9
10
12
12
www.SuKHamburg.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SK2048USD and is the answer not in the manual?

Questions and answers

Summary of Contents for Schäfter+Kirchhoff SK2048USD

  • Page 1: Table Of Contents

    Line Scan Camera SK2048USD Manual (v. 7.2012) Monochrome Line Scan Camera • Robust input and output connections SK2048USD • Hot-pluggable • Ultimate in mobility 2048 pixels, 14 µm x 14 µm, 15 MHz pixel frequency Interface: USB 2.0 Camera SK2048USD...
  • Page 2: Connections

    Line Scan Camera SK2048USD Manual (v. 7.2012) 1. Introducing the SK2048USD Line Scan Camera The line scan camera SK2048USD is designed for ultimate Once the camera driver and the SkLineScan ® program have portability. The robustly attached dedicated connections been loaded from the SK91USB-WIN CD then the camera enable external synchronization of the camera and the output can be parameterized.
  • Page 3: Hardware And Software Installation

    5. Follow the dialog instructions and finish the installation of SkLineScan. 6. Once installed, start SkLineScan. - The About dialog confirms that the "SK2048USD" camera is ready for use and the oscilloscope display window of the camera signal will open.
  • Page 4: Camera Control And Measurements

    4.3 Generating a 2D Image – Scanning a Surface A two-dimensional image is generated by moving the object The camera SK2048USD has a maximum line frequency of or the camera. The direction of the translation movement 14.10 kHz and the programmable range for the exposure must be orthogonal to the sensor axis of the CCD line scan period is 0.07 ms up to 35.0 ms.
  • Page 5 Line Scan Camera SK2048USD Manual (v. 7.2012) 4.4 Anti-blooming Adjustment The optimum anti-blooming effect and greatest dynamic range for the camera are obtained when the output voltage of the camera is at ~90% of the saturation voltage V Line scan signal with centrally enhanced illumination and sharply rising signal edges.
  • Page 6 Line Scan Camera SK2048USD Manual (v. 7.2012) 5. Sensor Performance Specifications Manufacturer: Dalsa Type: IL-P3-B 2048 Data source: Dalsa Linear Sensor Document 03-036-00187-09 Pin-out and Dimensions Page...
  • Page 7 Line Scan Camera SK2048USD Manual (v. 7.2012) Block Diagram and Typical Performance Data Page...
  • Page 8 Line Scan Camera SK2048USD Manual (v. 7.2012) Performance Specifications Page...
  • Page 9: Clamp Set Sk5102

    Line Scan Camera SK2048USD Manual (v. 7.2012) 6. Dimensions Line scan cameras with USB interface CCD line scan camera, digital Ø 65 61.5 M40x0.75 2.5 6 12.7 Casing group: Pixel No.1 Lens thread: M40x0.75 Distance to sensor: 19.5 mm Input control:...
  • Page 10: Line Scan Camera Fundamentals

    Line Scan Camera SK2048USD Manual (v. 7.2012) 7. Line Scan Camera Fundamentals Line scan cameras from Schäfter+Kirchhoff are supplied factory-preset for the particular application, with optional accessories and appropriate software – for parameterization of the camera or for optimizing signal acquisition. The advantages and constraints of the technology are described below and some essential aspects of sensor alignment, lens focussing and signal optimization are presented.
  • Page 11 Line Scan Camera SK2048USD Manual (v. 7.2012) 7.2 Alignments and Adjustments Sensor Alignment For linear illumination sources, rotating the line sensor results in asymmetric vignetting. The camera and illumination optics can be aligned optimally by monitoring the object illumination using the oscilloscope display. Sensor and...
  • Page 12: Warranty

    Line Scan Camera SK2048USD Manual (v. 7.2012) 8. Warranty 9. Accessories This manual has been prepared and Mounting bracket reviewed as carefully as possible but SK5105 Order Code no warranty is given or implied for any Warp-resistant construction for mounting the line...

Table of Contents