Maruson UltimaPro 33 Series User Manual

On-line ups

Advertisement

UltimaPro 33 Series
On-line UPS
USER MANUAL
Maruson T echnology Corporation
1351 Titan Way, Brea, CA92821, U.S.A.
Toll Free : 1-888-MARUSON
Tel : +1-714-870-6888
Fax : +1-714-870-4888
Website:
www .MarusonUSA.com
E-Mail:
Info@MarusonUSA.com
*All trademarks are the property of their respective owners.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UltimaPro 33 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Maruson UltimaPro 33 Series

  • Page 1 UltimaPro 33 Series On-line UPS USER MANUAL Maruson T echnology Corporation 1351 Titan Way, Brea, CA92821, U.S.A. Toll Free : 1-888-MARUSON Tel : +1-714-870-6888 Fax : +1-714-870-4888 Website: www .MarusonUSA.com E-Mail: Info@MarusonUSA.com *All trademarks are the property of their respective owners.
  • Page 2 Please comply with all warnings and operating instructions in this manual. This equipment should only installed, serviced, maintained by qualified personnel. Do not operate this unit before reading through all safety information and operating instructions carefully. Disclaimer We assumes no responsibility or liability for loss or damages, whether direct, indirect, consequential or incidental, which might arise out of the use of such information.
  • Page 3: Table Of Contents

    Table of Contents 1. SAFETY AND EMC INSTRUCTIONS ....................1 1-1. T ....................... 1 RANSPORTATION AND TORAGE 1-2. P ............................1 REPARATION 1-3. I ............................1 NSTALLATION 1-4........................ 2 ONNECTION ARNINGS 1-5. O ............................3 PERATION 1-6. S ............................3 TANDARDS 2.
  • Page 4: Safety And Emc Instructions

    1. Safety and EMC instructions All safety instructions in this document must be read, understood and followed. 1-1. Transportation and Storage Please transport the UPS system only in the original packaging to protect against shock and damage. The UPS must be stored in the room where the temperature is well regulated. Ambient temperature should not exceed 40°C.
  • Page 5: Connection Warnings

    1-4. Connection Warnings • There is no standard backfeed protection inside of the UPS. However, there are relays on the Input to cut off line voltage and while the neutral is still connect to UPS. Input relay diagram Input relay diagram for dual-input model •...
  • Page 6: Operation

    1-5. Operation Do not disconnect the grounding/earthing conductor cable on the UPS or the building wiring terminals under any circumstance. The UPS system features its own, internal current source (batteries). The UPS output sockets or output terminal blocks may be electrically live even if the UPS system is not connected to the building mains/live wires.
  • Page 7: Installation And Operation

    2. Installation and Operation These series came with two VAC systems: 208V and 400V. There are two different types of models: standard and long-run models. Please refer to the following table. VAC System Model Type Model Type LV 10K LV 10KL LV 10K DUAL LV 10KL DUAL LV 15KL/ LV 20KL...
  • Page 8: Wiring Terminal View

    2-2. Wiring Terminal View Diagram 1: LV10K(L)/HV 10K(L)/15K(L)/ Diagram 2: LV 10K(L)/HV 10K(L)/15K(L) 20K(L) Rear Panel 20K(L) DUAL Rear Panel Diagram 3: LV10K(L)/HV 10K(L)/ 20K(L) Diagram 4: LV10K(L)/HV 10K(L)/ 20K(L) Input/Output Terminal DUAL Input/Output Terminal...
  • Page 9 Diagram 5: HV 30K(L)/40K(L)/ Diagram 6: HV 30K(L) DUAL/ 40K(L) DUAL/ LV 15K(L)/LV 20K(L) Rear Panel LV 15K(L) DUAL/LV 20K(L) DUAL rear panel Diagram 7: HV 30K(L)/40K(L)/LV 15K(L) Diagram 8: HV 30K(L) DUAL / 40K(L) DUAL LV 20K(L) Input/output terminal LV 15K(L) DUAL /LV 20K(L) DUAL Input /Output Terminal...
  • Page 10 Diagram 9: HV 60KL/LV 30KL front view Diagram 10: HV 80KL/LV 40KL front view with door open with door open Diagram 13: HV 60KL/HV 80KL/LV 30KL/LV 40KL Input/Output Terminal...
  • Page 11 Diagram 14: HV 60KL DUAL/LV 30KL DUAL Diagram 15: HV 80KL DUAL/LV 40KL DUAL front view with door open front view with door open 1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector) 4.
  • Page 12 18. Output switch 19. Dry contact communication port (optional) 2-3. Single UPS Installation Installation and wiring must be carried out in accordance with the local electric laws and regulations by trained professionals. Make sure that the mains wire and breakers of the building are rated for the capacity of the UPS to prevent electric shock or risk of fire.
  • Page 13 NOTE 6: The cable for HV 60KL, HV 60KL DUAL, LV 30KL and LV 30KL DUAL should be able to withstand over 120A current. It is recommended to use AWG 4 or thicker wire for Phase and AWG 1 or thicker wire for Neutral for safety and efficiency.
  • Page 14 Terminal block wiring diagram for HV 30K(L)/40K(L) and LV 15K(L)/20K(L) Terminal block wiring diagram for HV 30K(L) /40K(L) DUAL and LV 15K(L) DUAL/20K(L) DUAL Terminal block wiring diagram for HV 60KL/80KL and LV 30KL/40KL...
  • Page 15 Terminal block wiring diagram for HV 60KL/80KL and LV 30KL DUAL/40KL DUAL Battery wires connection schematic NOTE 1: Make sure that the wires are connected securely with the terminals. NOTE 2: Please install the output breaker between the output terminal and the load, and the breaker should have leakage current protective function if necessary.
  • Page 16: Ups Installation For Parallel System

    numbers of the battery in a chain, make sure you modify the UPS setting accordingly. Connection with wrong battery voltage may cause irreversible damage of the UPS. ● Pay special attention to the polarity marking on external battery terminal block. Connection with wrong battery voltage may cause irreversible damage of the UPS.
  • Page 17 Wiring diagram of parallel system for HV 30K(L)/40K(L) and LV 15K(L)/20K(L) Wiring diagram of parallel system for HV 30K(L)/40K(L) DUAL and LV 15K(L)/20K(L) DUAL Wiring diagram of parallel system for HV 60KL/80KL and LV 30KL/40KL...
  • Page 18: Software Installation

    Wiring diagram of parallel system for HV 60KL/80KL DUAL and LV 30KL DUAL/40KL DUAL 2-5. Software Installation For optimal computer system protection, install UPS monitoring software to configure UPS shutdown operation.
  • Page 19: Operations

    3. Operations 3-1. Button Operation 1) Before operation, make sure that the two strings of batteries are connected correctly in order of ”+,GND,-” terminals and the breaker of the battery pack is at “ON” position (only for long-run model). 2) Press the “ ”...
  • Page 20 96 72.07 After initialization, the main screen will display as shown below. On the button, there are five icons to represent five sub-menus: Control, measure, setting, information, data log. 3-2-2. Control screen Touch the icon to enter control sub-menu. 20KVA 19:52:36 Bypass Mode 2018-11-07...
  • Page 21 Enter No Or Back Confirm YES Turn ON /OFF UPS Enter No Or Back Confirm YES Do Battery Test Enter No Or Back Confirm YES Do MUTE ALL Enter No Or Back Confirm YES Turn ON/OFF CHARGER Screen 1.0 «Control» and its sub-menus On/Off UPS ...
  • Page 22 Audio mute  It will show “Mute all” if the audio is active. Touch “Yes” to activate mute. If “Mute all” is active, it will show icon on the top left corner of the main screen. Touch “Back” to return to CONTROL screen immediately or “No”...
  • Page 23 Measure screen page 1 LINE VOL: The real time value of R, S and T phase voltage, RS/ST/TR voltage and input frequency.  INVERTER VOL: The real time value of R, S and T inverter voltage, RS/ST/TR voltage and frequency. ...
  • Page 24 Measure screen page 3 INPUT W: R, S and T input power in watt.  INPUT VA: R, S and T input power in VA.  INPUT W (%): R, S and T input power watt in percentage.  INPUT VA (%): R, S and T input power VA in percentage. ...
  • Page 25 General Setting Setting screen page 1 Date/Time: Set the date and time. The format is YYYY-MM-DD HH:MM:SS. The calendar day will be  automatically changed when the year, month and date are set. Language: Set the LCD language. There are three options: English, Simplified Chinese and Traditional ...
  • Page 26 icon on the top right corner of the main screen. Mode Mute: UPS status mode alarm enable/disable. If “Mode Mute” is activated, it will show  icon on the top right corner of the main screen. Advance Setting Advance Password Page It’s required to enter password (4 digits) to access to the “ADVANCE”...
  • Page 27 There are three sub-menus under “AdvanceUser” setting: ELECTRONIC, BATTERY and MISCELLANEOUS. ELECTRICAL Electrical Setting Page 1 Output VOL.: Select the output rated voltage.  If the UPS is HV system, there are four options, 208V, 220V, 230V and 240V.  If the UPS is LV system, there are two options, 120V and 127V.
  • Page 28 available when “Bypass forbid.” is set to “Disable”. Enable: Bypass enabled. When selected, bypass mode is activated.  Disable: Bypass disabled. When selected, no output through bypass when manually turning off  the UPS. Bypass Voltage Range: Set the bypass voltage range. ...
  • Page 29 MISCELLANEOUS Miscellaneous setting page Auto Restart:  Enable: After “Enable” is set, once UPS shutdown occurs due to low battery and then utility  restores, the UPS will return to line mode. Disable: After “Disable” is set, once UPS shutdown occurs and the utility restores, the UPS will ...
  • Page 30 your local dealer to get maintainer password. CAUTION: This setting menu is only for qualified technician. Otherwise, mis-operation will cause UPS damage. There are five sub-menus under “AdvanceMaintainer” setting: SYS PARAMETER, INSTALL INFO, VOL CALI, CURR CALI, INITIAL, ELECTRONIC, BATT, MISCELLANEOUS and UPS SELFTEST. SYS PARAMETER SYS PARAMETER Page 1 Mode Name: Set the UPS model name.
  • Page 31 INSTALL INFO INSTALL INFO Page  SYS Install Date: Set the date of UPS installation.  BAT Install Date: Set the date of Battery installation. VOL CALI VOL CALI Page1  Bus VOL: BUS voltage calibration. Click value columns and it will pop up .
  • Page 32  Line VOL: Line voltage calibration. Click value columns and it will pop up . Then, each click is 0.1% no matter it’s pressing up or down key . Press “up” key to increase 0.1% and press “down” key to decrease 0.1%.
  • Page 33 INITIAL INITIAL menu Page INITIAL DATA LOG Page DATA LOG: After clicking “DATA LOG”, it will pop up a message board as shown in above screen. Touch  “YES” to clear the DATALOG page. Touch “Back” or “No” to cancel this operation and back to INITIAL menu page.
  • Page 34 INITIAL  CALI Page CALI: After clicking “CALI”, it will pop up a message board as shown in above screen. Touch “YES” to  restore default calibration value. Touch “Back” or “No” to cancel this operation and back to INITIAL menu page.
  • Page 35 ELECTRICAL Electrical Setting Page 1 Output VOL: Select the output rated voltage.  When UPS is HV system, there are four options, 208V , 220V ,230V and 240V.  When UPS is LV system, there are two options, 120V and 127V. ...
  • Page 36 setting range is 96V ~ 110V when the UPS is LV system. H: High voltage point for bypass. The setting range is 231V ~ 264V when the UPS is HV system.  The setting range is 139V ~ 146V when the UPS is LV system. Bypass FRE Range: Set the bypass frequency range.
  • Page 37 MISCELLANEOUS Miscellaneous setting page Auto Restart:  Enable: After “Enable” is set, once UPS shutdown occurs due to low battery and then utility  restores, the UPS will return to line mode. Disable: After “Disable” is set, once UPS shutdown occurs and the utility restores, the UPS will ...
  • Page 38 screen, all tested items are shown “unknown”. Simply click “UPS SELFTEST” button, the UPS will start self-test. If the UPS is normal, it will show “Normal” in all columns. Otherwise, “Unknown” will be displayed in the columns. 3-2-5. Information screen Touch the icon to enter information page.
  • Page 39 Rated Information Page Rated Information Output VOL: It shows output rated voltage.  Output FRE: It shows output rated frequency.  CVCF Mode: Enable/Disable CVCF mode.  Bypass Forbid: Enable/disable bypass function.  Bypass at UPS Off: Enable/disable auto bypass function when UPS is off. ...
  • Page 40 Parameters Information Page 2 BATT Mode Work Time: The maximum discharge time in battery mode.  BATT Warning VOL:  HIGH: High battery warning voltage.  LOW: Low battery warning voltage.  Shutdown Voltage: If battery voltage is lower this point, UPS will automatically shut down. ...
  • Page 41: Audible Alarm

    3-2-6. Data Log screen Touch the icon to enter date log page. Data log is used to record the warning and fault information of the UPS. The record contains date & time, code, type and description. Touch the icon page up or down if there are more than one page in the date log. Touch the icon to return to main screen.
  • Page 42 is normalized, the UPS will auto restart in AC mode. 2. Turn on the UPS without utility power supply (in Battery mode) 1) Make sure that the two strings of batteries are connected correctly in order of ”+,GND,-” terminals and the breaker of the battery pack is at “ON” position (only for long-run model). 2) Press the “...
  • Page 43: Parallel Operation

    7. Turn off the UPS with utility power supply in AC mode 1) Touch “CONTROL” and select “Turn off UPS” icon to turn off the UPS. Refer to “UPS on/off” screen. NOTE 1: If the UPS has been set to bypass output, it will bypass voltage from the mains to output terminal even though you have turned off the UPS (inverter).
  • Page 44 4) Turn on the parallel system in AC mode: Turn on the line input breaker of each UPS. If using dual-input unit, please also turn on the external bypass input breaker. After all UPSs enter into bypass mode, measure the output voltage between two UPSs for the same phase to make sure the phase sequence is correct.
  • Page 45: Fault Code

    ● When parallel system is turned on, please do not operate the maintenance switch of any unit. ● The parallel system DOES NOT support ECO mode. Therefore, please DO NOT “enable” ECO mode in any unit. 3-6. Fault Code Fault code Fault event Icon Fault code...
  • Page 46: 3-7.Warning Code

    3-7.Warning Code Warning code Warning event Warning code Warning event Line situations are different in parallel Battery unconnected system Bypass situations are different in IP Neutral loss parallel system Locked in bypass after overload 3 IP phase abnormal times in 30 minutes Bypass phase abnormal Converter current unbalanced Over charge...
  • Page 47: Trouble Shooting

    4. Trouble Shooting If the UPS system does not operate correctly, please solve the problem by using the table below. Symptom Possible cause Remedy No indication and alarm in the front The AC input power is not Check if input cable firmly display panel even though the mains is connected well.
  • Page 48: Storage And Maintenance

    5. Storage and Maintenance 5-1. Storage Before storing, charge the UPS at least 7 hours. Store the UPS covered and upright in a cool, dry location. During storage, recharge the battery in accordance with the following table: Storage Temperature Recharge Frequency Charging Duration -25°C - 40°C Every 3 months...
  • Page 49: Specifications

    6. Specifications 400V 15K(L) 10K(L) 15K(L) DUAL 30K(L) 40K(L) 60KL 80KL MODEL 10K(L) DUAL 20K(L) 30K(L) DUAL 40K(L) DUAL 60KL DUAL 80KL DUAL 20K(L) DUAL 15KVA / 15KW CAPACITY* 10KVA / 10KW 30KVA / 30KW 40KVA / 40KW 60KVA / 60KW 80KVA / 80KW 20KVA / 20KW INPUT Low Line Loss...
  • Page 50 208V 15K(L) 20K(L) 30KL 40KL MODEL 10K(L) 15K(L) DUAL 20K(L) DUAL 30KL DUAL 30KL DUAL 10KVA CAPACITY* 15KVA / 15KW 20KVA / 20KW 30KVA / 30KW 40KVA / 40KW /10KW INPUT 70 VAC(Ph-N) ± 3 % at 50% Load Low Line Loss 88 VAC(Ph-N) ±...