In order to fully disconnect the UPS system, first press the OFF/Enter button to disconnect the mains. Prevent no fluids or other foreign objects from inside of the UPS system. Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
Do not open or destroy batteries. Escaping electrolyte can cause injury to the skin and eyes. It may be toxic. Please replace the fuse only with the same type and amperage in order to avoid fire hazards. Do not dismantle the UPS system. Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
6. Emergency power off (EPO) function connector 7. USB communication port 8. RS-232 communication port 9. SNMP intelligent slot 10. External battery connector (only available for long run-time models) 11. Input terminal 12. Output circuit breaker Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords. Step 2: UPS output connection For socket-type outputs, there two kinds of outputs: programmable outlets and general outlets. Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
Page 7
Step 7: Installing software For optimal computer system protection, install UPS monitoring software to fully configure UPS shutdown. Please follow steps below to download and install monitoring software: Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
Remove the top cover of After replacing the Re-connect all battery wires. battery box and replace the batteries, put the battery batteries inside. box back to the original location and screw it tightly. Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
Step 4: Cover the other side of plastic shell as one side of plastic shells. below chart. Battery kit is now assembled. 3-battery kit Step 1: Remove adhesive tapes. Step 2: Connect all battery terminals by following below chart. Tapes Tapes Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
Page 10
Tapes Tapes Step 3: Put assembled battery packs on Step 4: Cover the other side of plastic shell as one side of plastic shells. below chart. Battery kit is now assembled. Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
Page 11
Tapes Tapes Step 3: Put assembled battery packs on Step 4: Cover the other side of plastic shell as one side of plastic shells. below chart. Battery kit is now assembled. Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
Select buttons simultaneously for 5 seconds. Then UPS will enter to Button bypass mode. This action will be ineffective when the input voltage is out of acceptable range. 3.2. LCD Panel Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
Page 13
Indicates that the UPS alarm is disabled. Indicates the battery charger is working. Battery Information Indicates the Battery level by 0-25%, 26-50%, 51-75%, and 76-100%. Indicates low battery. Indicates there is something wrong with battery. Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
Rack display Tower display Low battery Overload Battery is not connected Overcharge Site fault Over temperature Charger failure Battery fault Frequency unstable in Bypass mode Input voltage is out of bypass range Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
BAT 60: presents output frequency at 60Hz If converter mode enable, you may choose the following output frequency: CF 50: presents output frequency at 50Hz CF 60: presents output frequency at 60Hz Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
Page 17
55/150 alternating flashing: acceptable input voltage range is from 55V to 150V; 80/130 alternating flashing: acceptable input voltage range is 80V to 130V; 85/135 alternating flashing: acceptable input voltage range is 85V to 135V; 00: Exit setting Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
When input voltage is within acceptable range but UPS is Bypass overloaded, UPS will enter Bypass mode mode. Bypass mode can also be set by the front panel. Alarm is will beep every 10 seconds. Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
EPO enable Beeps every second Over temperature Beeps every second Charger failure Beeps every second Battery Fault Beeps every second Bypass Out Range Beeps every second Bypass Frequency Unstable Beeps every second Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
Remove excess loads from the UPS is locked in Bypass UPS output first. Then shut mode. Connected devices down the UPS and restart are fed directly by the the UPS. mains. Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
During storage, recharge the battery in accordance with the following table: Storage Temperature Recharge Frequency Charging Duration -25°C - 40°C Every 3 months 1-2 hours 40°C - 45°C Every 2 months 1-2 hours Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...
20-90 % RH @ 0- 40°C (non-condensing) Noise Level Less than 50dBA @ 1 Meter MANAGEMENT Smart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC Optional SNMP Power management from SNMP manager and web browser Maruson Technology Corporation ULTIMA RACK/TOWER SERIES 1K-3KVA |...