E) Auxiliary Control/Status - Whelen Engineering Company WPS-2900 Series Installation Manual

High power voice & siren system
Table of Contents

Advertisement

e) Auxiliary Control/Status (optional)
The WPS-2900 may be equipped with an optional module that allows the user to remotely
control siren functions and to remotely collect siren status information. The following
Whelen commands are supported:
Cancel (or Clear)
Wail
Attack
Alert
Public Address
Air Horn
Hi/Low
* = Not available for the WPS-2900
The following status bits are supported with Normally Open relay closures:
AC
AC Voltage is present
DC
DC Voltage level is good
Partial
At least one amplifier is active
Full
All amplifiers and drivers are active
Rotor
Rotor Active
Intrusion
Intrusion active
In addition to commands and status functions, the Auxiliary Control/Status Option has
transformer coupled circuits for accepting audio. One circuit is active in conjunction with
the Public Address command, while the other circuit is used for local audio, such as a local
microphone or paging system. The local audio must have a "Push To Talk" contact closure
for operation. In either case the audio is broadcast over the system.
To activate one of the supported commands, simply make a closure between the desired
command input and ground. Typically, a relay is used to make a remote connection. An
open collector device may be used, as long as it meets the electrical specifications of this
document.
When an input is activated by a momentary closure, the siren function will run for the pre
programmed time or until another command is activated. For example, the Cancel
command will override a warning tone and silence the siren. Note that if a closure is
maintained, it can not be overridden.
Whoop
Noon Test
Digital Voice Messages
(1 - 16)
Silent Test
Silent Test Clear
North*
Page 34
East*
South*
West*
Clockwise*
Counter-Clockwise*
Strobe On
Strobe Off

Hide quick links: