7.3

Cable lengths

Table 7-10
Cable type
IE TP torsion cable
IE FC TP Marine Cable
IE FC TP Trailing Cable
IE FC TP Flexible Cable
IE FC TP standard cable
Table 7-11
Cable type
IE FC standard cable, 4×2, 24
AWG
IE FC flexible cable, 4×2, 24
AWG
IE FC standard cable, 4×2, 22
AWG
IE FC flexible cable, 4×2, 22
AWG
Table 7-12
Permitted cable lengths (fiber-optic cable - Fast Ethernet)
Device variant
Fiber-optic cable type Permitted cable length
X304-2FE,
50/125 µm
X320-1 FE
multimode fiber
62.5/125 µm multi‐
mode fiber
X306-1LD FE
9/125 µm
single mode fiber
X310FE
-
X320-3LD FE
50/125 µm
multimode fiber
9/125 µm
single mode fiber
SCALANCE X-300
Compact Operating Instructions, 11/2019, A5E00982643-18
Permitted cable lengths (copper cable - Fast Ethernet)
Accessory (plug, outlet, TP cord) Permitted cable length
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC RJ-45 Plug 180
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC RJ-45 Plug 180
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC RJ-45 Plug 180
Permitted cable lengths (copper cable - gigabit Ethernet)
Accessory (plug, outlet, TP cord) Permitted cable length
with IE FC RJ-45 Plug 180,
4x2
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC Outlet RJ-45
+ 10 m TP cord
0 to 5 km
0 to 5 km
0 to 26 km
-
0 to 5 km
0 to 26 km
0 to 45 m
+ 10 m TP cord
0 to 55 m
0 to 75 m
+ 10 m TP cord
0 to 85 m
0 to 90 m
+ 10 m TP cord
0 to 100 m
0 to 90 m
0 to 60 m
+ 10 m TP cord
0 to 90 m
+ 10 m TP cord
Attenuation
≤1 dB/km at 1300 nm; 1200 MHz×km; maximum in‐
sertion loss 0.5 dB; 9 dB max. permitted FO cable
attenuation at 3 dB link power margin
≤1 dB/km at 1300 nm; 1200 MHz×km; maximum in‐
sertion loss 0.5 dB; 9 dB max. permitted FO cable
attenuation at 3 dB link power margin
≤0.5 dB/km at 1310 nm; maximum insertion loss 0.5
dB; 14 dB max. permitted FO cable attenuation at 2
dB link power margin
-
≤1 dB/km at 1300 nm; 1200 MHz×km; maximum in‐
sertion loss 0.5 dB; 9 dB max. permitted FO cable
attenuation at 3 dB link power margin
≤0.5 dB/km at 1310 nm; maximum insertion loss 0.5
dB; 14 dB max. permitted FO cable attenuation at 2
dB link power margin
Technical data