8.5 Removal / installation of the control unit

!
Removing the control unit
Lift the cover and secure the insert with a screw
driver against snapping back. Locate the cover
clip and pull clip to release. Remove cover.
Unscrew all three locking screws (two screws for
the TurfCup version) and remove control unit
cover.
Unclip control unit from protective casing and
lift up and out.
To remove vent hose, push back mounting ring
and pull out hose.
Clean, repair, or replace as needed.
Replacing the control unit
A replacement control unit is supplied with plug-and-socket connections. Push hose into plug-in
sockets as far as it will go and ensure that the mounting ring springs back.
Clip control unit into protective casing.
Secure housing cover using all three screws (two screws for TurfCup version).
Check sprinkler is working properly per Start-Up procedure (6.2).
Ensure sprinkler is not under pressure.