Image 5-2 Condensation Water Drain For Vertical Mounting; Image 5-3 Condensation Water Drain For Horizontal Mounting - Siemens SIMOTICS FD 1LL1 Operating Instructions Manual

Induction motor
Table of Contents

Advertisement

Allow the condensation water to discharge for vertical placement
In the DE bearing shield, water drain holes are located in the area of the mounting feet or
opposite the regreasing system. They are sealed with screw plugs.
Image 5-2
Condensation water drain for vertical mounting
Allow the condensation water to discharge for horizontal placement
The water drain holes are located in the lower side of the stator enclosure, and sealed with
screw plugs.
Image 5-3
To drain the condensation water, proceed as follows:
1. Remove the screw plugs to allow the condensation water to drain.
2. Then reinsert the screw plugs.