Thermal Motor Protection; Thermal Motor Protection Using Ptc Thermistors (Option); Interlock Circuit For The Automatic Regreasing System (Option); Interlock Circuit For Anti-Condensation Heating - Siemens SIMOTICS FD 1LL1 Operating Instructions Manual

Induction motor
Table of Contents

Advertisement

4.6

Thermal motor protection

The machine is equipped with measuring equipment for direct monitoring of the motor
temperature to protect the machine against overload during operation. Plan a corresponding
circuit for monitoring.
4.7

Thermal motor protection using PTC thermistors (option)

The machine is equipped with PTC thermistors for direct monitoring of the motor temperature
to protect the machine against overheating during operation. Plan a corresponding circuit for
monitoring.
4.8

Interlock circuit for the automatic regreasing system (option)

Relubrication is permitted only for a rotating shaft. Consequently, deploy an interlock circuit
for machines with automatic regreasing system to prevent them from operating at machine
standstill.
4.9

Interlock circuit for anti-condensation heating

If the anti-condensation heating is operated while the machine is running, this can increase
the temperatures inside the machine.
● Install an interlock circuit that switches off the anti-condensation heating once the main
● Only switch on the anti-condensation heating after the motor has been switched off.
SIMOTICS FD 1LL1
Operating Instructions 04/2016
machine is switched on.
Carefully comply with the data on the anti-condensation heating plate.
4.9 Interlock circuit for anti-condensation heating
Preparations for use
31

Advertisement

Table of Contents
loading

Table of Contents