Ecoflam Linda+ 24 CS CPR Installation Instructions Manual
Ecoflam Linda+ 24 CS CPR Installation Instructions Manual

Ecoflam Linda+ 24 CS CPR Installation Instructions Manual

Wall-hung instantaneous premixed gas thermal unit sealed boiler with forced flow
Hide thumbs Also See for Linda+ 24 CS CPR:

Advertisement

WALL-HUNG INSTANTANEOUS PREMIXED GAS THERMAL UNIT
SEALED BOILER WITH FORCED FLOW
24 CS CPR
28 CS CPR
G A S T E C
LB 1113 • 06/05/2002

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Linda+ 24 CS CPR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ecoflam Linda+ 24 CS CPR

  • Page 1 WALL-HUNG INSTANTANEOUS PREMIXED GAS THERMAL UNIT SEALED BOILER WITH FORCED FLOW 24 CS CPR 28 CS CPR G A S T E C LB 1113 • 06/05/2002...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS GENERAL INFORMATION This manual is an integral and essential part of the product. It should be GENERAL INFORMATION kept with the appliance so that it can be consulted by the user and our authorised personnel. Please carefully read the instructions and notices about the unit con- 1.1 G ENERAL NSTRUCTIONS...
  • Page 3: Overall View

    2. INSTALLATION VERALL HE INSTALLATION AND INITIAL START UP OF THE BOILER MUST BE CARRYED OUT BY UTHORISED ERSONNEL ONLY IN COMPLIANCE WITH NATIONAL LOCAL AND ALL OTHER INSTALLATION STANDARDS WHICH ARE CURRENTLY IN EFFECT 2.1 INSTRUCTIONS BEFORE INSTALLATION This is an appliance for the production of Domestic hot water reaching a temperature lower than the boiling temperature .
  • Page 4: Clearances

    - Position the wire in the dope rubber in order it engages on the con- LEARANCES trol panel. - The blue wire (neutral) must be connected to the terminal marked In order to allow for access to the interior of the boiler for main- with "...
  • Page 5 The size of the pipes for the heating system must take into considera- In addition, it is also possible to use a split (twin pipe) system by fitting tion that the residual head avaiable is represented in the chart in func- a special adaptor to the flue connector and using the aperture for the tion of the flow rate.
  • Page 6: Room Thermostatc

    Linda 24 CS CPR Exhaust Restrictor Maximum Risk of Condensation Forming Type ø 43 mm Restrictor Extension Piping not insulated Piping insulated Exhaust/Air ø 43 restrictor no ø 43 restrictor no C12 (xy) Twin Pipe L min = 11,5 m 43 m 4,3 m 6,9 m...
  • Page 7: Electrical

    2.11 LECTRICAL IAGRAM EGEND A01 = Circulation Pump A = Time Clock Connector A02 = B = Central Heating Selection (Winter) and temperature A03 = Spark Generator/Gas Valve Supply Adjustment A04 = Gas Valve Supply C = Diagnosis connector A05 = Motorised Diverter Valve D = Domestic Hot Water Temperature Adjustment A06 =...
  • Page 8: Water Circuit Diagrams

    2.12 ATER IRCUIT IAGRAM EGEND Main Heat Exchanger Over Temperature Thermostat Burner Ignition Electrodes Detection Flame Electrode Motorised Valve Heating Probe Main Circuit Flow Switch Automatic By-pass Domestic Hot Water Temperature Probe Secondary Heat Exchanger Gas Valve Domestic Hot Water Flow Switch Domestic Water Inlet Filter Water Inlet Valve Manometer...
  • Page 9: Commissioning

    COMMISSIONING ONTROL ANEL MPORTANT BEFORE ANY INTERVENTION IN THE BOILER IT IS NECESSARY TO SWITCH OFF THE ELECTRICAL SUPPLY TURNING THE EXTERNAL SWITCH ON " O " ( OFF ). NITIAL REPARATION RESET Preliminary electrical system checks to ensure electrical safety must be carried out by a competent person i.e.
  • Page 10: Initial Start Up

    3.4. I NITIAL TART HE CHECKS TO BE RUN BEFORE INITIAL START UP ARE AS FOLLOWS 1. Make sure that: the screw on the automatic air valve has been loosened when the system is full; If the water pressure in the system is below 1 bar, bring it up to the appropriate level;...
  • Page 11: Raining The

    to domestic hot water and the burner ignites at the minimum RAINING THE YSTEM power until the boiler water reaches a temperature of about 50°C. This device operates only if the boiler is functioning perfectly and: - the system pressure is sufficient; RAINING THE EATING YSTEM...
  • Page 12: Maintenance

    230 / 50 Total electrical power absorbed Protection grade of electrical system ECOFLAM S.p.A. reserves the right to make any adjustments, without prior notice, which it considers necessary or useful to its products, without affecting their main features. Ecoflam S.p.A.

This manual is also suitable for:

Linda+ 28 cs cprLinda+ 24 ca cprLinda+ 28 ca cpr