ELECTRICAL CONNECTIONS

Carefully read the diagram No. 2197 pic. 10 for the electrical connections of the signal lamp "LAPI 2", the keyswitch "SECH 15", the
photo cells "TRIFO 1 1" and the magnetic loop detector for fully automatic operations.
Once satisfied that all the connections have been properly done, the first running test can be carried out. You can pulse the barrier open
either by key or remote control. A complete working cycle includes rising-stop-lowering by pulse. Automatic lowering is by closing the
hook switch "B" to "ON" position. If set to "OFF", a pulse is required to lower the beam. The maximum running time of the electric motor
is 60 seconds; it is a fixed time and cannot be varied. Timer 6 is to set the duration of the stop phase, ie. the dwell time before automatic
re-closing to meet the installation requirements. The barrier can be operated at a distance by remote control. Fit the radio receiver card
"ASTRO 43" into the provided connector on the PC board of the electronic control box. Fix the aerial in the most suitable position to
ensure proper receipt of the radio signal from the transmitter and connect the coaxial cable to the connector shown in pic. 8.
PIC. 7
OPTIONAL:
IMPORTANT
THE HIGH VOLTAGE CUT OFF SWITCH IS FITTED BETWEEN THE ARM OF THE
CONTROL BOX AND THE DOOR.
WHEN THE DOOR IS OPENED, THE 230 V-50 Hz POWER SUPPLY IS INTERRUPTED
AUTOMATICALLY FOR SAFETY REASONS.
IT IS RECOMMENDED TO CONNECT ALL THE EARTH WIRES TO THE PROPER
TERMINAL.
6
RADIO TRANSMITTER
CEI
STANDARDS
TERMINAL FOR
CHANNEL 2
PC BOARD N° 2197
230 V - 50 Hz
POWER SUPPLY
SWITCH
ELPRO 88 exp
SWITCH TO CUT OFF
THE HIGH VOLTAGE SUPPLY
AERIAL
COAXIAL CABLE
ASTRO 43/2 CARD
PIC. 8
RIGHT-HAND
PIC. 9

Advertisement