Setup Menu Items

Setup Item
SET: Panel LED
SET: Disp Lamp
SET: AC PowerUp
SET: Touchpanel
SET: Touchsense
SET: Front IR
SET: Verbosity
SET: Volume
Preset
Volume & Tone Control
The volume control ranges from 0 to 99. At level 99, the output level equals the
input level for a unity gain. For bass and treble, 50 is used for a "flat" frequency
response. Maximum is 99 and minimum is 00.
Controls the entire front panel LEDs. Default is ON.
Sets the display brightness to 1 of 4 levels. Default
is 100% (full brightness).
Controls what the matrix does when AC power is
first applied, and how it recovers from a power
outage.
ON (default) forces the unit to turn on, and the
previous switch state will be restored.
STANDBY causes the unit to enter Standby mode
when AC power is applied.
Enables or disables the front panel buttons.
Default is ON (enabled).
Controls the sensitivity of the front panel buttons.
Default is HIGH for fastest front panel response. A
lower setting reduces the risk for accidental button
pushes or false triggers by outside interference.
Enables or disables the front panel IR sensor. Set
to OFF to prevent spurious IR signals from
controlling the matrix. Default is ON (enabled).
Default is ON, where the matrix echoes responses
to any command (via serial, IR, or front panel).
When set to OFF, the matrix only echoes
responses to serial commands.
Note: Memory commands and mute commands will
always echo serial responses, regardless of this
setting
"SET TO 100%" will set all analog volumes to 99.
This option is for integrators who don't want to use
the Volume and Tone feature. Note: The USE
CURRENT option will not change any of the
volume settings.
15