Download Print this page

Programming Door Operator - ABON Ultra Series Operating Instructions Manual

Advertisement

Available languages

Available languages

Programming door operator

ATTENTION: The overload cut-out provides no
protection whilst programming the door operator!
Note: Programming is only possible during initial installation
or after resetting the door operator. Do not press any keys
during programming. DIP switch E-7 (relax drive belt tension)
must be in the OFF position during the programming phase.
Preparation: Connect door to door operator.
Programming with remote transmitter
At the time of delivery and after resetting the door
operator, the remote transmitter has the following
functionalities:
• 1 Safety control operation and fine adjustment "ON"
• 2 Safety control operation and fine adjustment "OFF"
• 3 and 4 confirmation (saving)
After the programming of the door
operator, key 1 is used for remote
control and the other keys can be
used to control other similar door
operators or other radio receivers.
Programming
• Press and hold key 1 and the
door moves in the open direction.
• If you have reached the desired end position "OPEN",
release key 1. (You can make corrections with key 2)
• Press key 3 once briefly, storage procedure: The door
operator automatically saves "End position OPEN /
CLOSE" and forces of the "Travel path OPEN / CLOSE".
The door operator lighting flashes alternately.
The storage is complete when the door is open and the door
operator lighting flashes.
Check the overload cut-out according to the chapter
on safety checks.
Programming without remote transmitter
On the door operator:
• Pull out the RJ-45 plug (6)
• Press and hold down "Pulse" (1)
key and the door moves in the open
direction.
• If you have reached the desired end
position "OPEN" position, release
"Pulse" (1) key
• Re-insert the RJ-45 plug (6) (You
can make corrections with the
"Pulse" (1) key)
• Press „Program" (2) key, Storage
procedure: The door operator
automatically saves "End position
OPEN / CLOSE" and forces of the "Travel path OPEN /
CLOSE". The door operator lighting flashes.
Storage is complete when the door is open and the door
operator lighting glows.
Check overload cut-out according to the chapter on
safety checks.
Ultra
Program/Delete remote transmitter
Programming remote
transmitter:
• Press the "Program" (2) key ,
LED (3) flashes once
• Within 20 sec, press a key on
the remote transmitter that
has not yet been
programmed, LED (3) lights
up and programming is
complete.
Delete (all) remote transmitter(s)
Press and hold "Program" (2) >key for 5 sec, LED (3) first
flashes slowly and then quickly and afterwards, it goes off. All
remote transmitters programmed have been deleted.
Operation
CAUTION. Mishandling of product can result in
injuries or material damage. Observe the basic safety
rules:
While opening or closing door, do not block travel areas
inside and outside. Keep children away.
The door movements can be activated or stopped through the
remote transmitter provided or through optionally
connectable switching elements such as the wall-mounted
push-button.
Optional external features (such as the emergency lock
release) can also be connected to the door operator.
The door must be connected before starting up
the operator. If it is not, incorrect force values
will be programmed into the electronic system. This can
cause malfunctions.
Settings / Options
Warning phase
If the warning phase is activated, activating the door operator
initially only switched on the door operator light.
3 seconds later, the motor starts running (factory setting is
0 seconds)
Adjusting the warning phase:
• Press the "Program" key (2) once. The red LED (3) will
flash once.
• Press the "Pulse" key (1) twice. The red LED (3) will flash
three times.
• Press the "Program" key (2) once. The warning phase is
now programmed.
9

Advertisement

loading

This manual is also suitable for:

Ultra s