Electrical Connections; Connecting The Mains Input To The Traco Power Supply Unit - Ametek Land NIR Series Installation Manual

Thermal imager
Table of Contents

Advertisement

Installation Guide
4

Electrical Connections

The electrical connections for the thermal imager power supply are made via
the 2-way socket on the rear of the thermal imager. See Figs. 5 & 6.
Electrical connection to the thermometer must be made via the pre-wired
plug and cable. The cable is screened. The screen is connected to the
connector shell, and thus to the camera body of the NIR. The screen must
also be grounded at the power supply. There are cable options available for
both length and termination at the power supply. For details, see Section 6
'Accessories for NIR Thermal Imagers'.
To connect the cable:
1)
Refer to Fig. 6. Align the red marker near the lugs of the pre-wired
plug with the red marker above the keyway in the socket on the thermal
imager.
2)
Push the plug into the socket.
To disconnect the cable:
1)
Grip the locking sleeve section of the plug.
2)
Pull the plug outwards to release the locking mechanism and disconnect
the cable.

4.1 Connecting the mains input to the TRACO Power Supply Unit

Fig. 7
The TRACO Power Supply Unit is supplied with a
3-pin AC input connector (Fig. 7). You will need to
disassemble this connector to install the cable.
1)
Unscrew the cover from the mains Input on
the Power Supply Unit.
NIR Thermal Imager
Page 7

Advertisement

Table of Contents
loading

Table of Contents