MAINTENANCE PROCEDURES - CONTROLS DIAGNOSTIC
Use the following procedure to diagnose a possible faulty or broken control switch. 2 small pieces
of strapping are needed for this procedure.
The diagnostics feature is enabled for 30 seconds. If all components have not been verified within
30 seconds repeat steps 1 through 4 and resume.
1.
Remove battery from tool.
2.
Turn tension control knob pointer to MODE.
3.
Squeeze feedwheel operating lever and insert a small piece of strap under the feedwheel.
Strap must be only under the feedwheel and NOT cover strap sensor.
4.
Insert battery while holding the operation button for approximately three seconds. LED will
flash 1 time indicating the button is working correctly.
5.
Turn tension control knob pointer to 5. Operation Button LED will flash 5 times indicating
tension knob is working correctly.
6.
Rotate tension control knob back to level MODE.
7.
Turn the tool on it's side. Place a small piece of strap over the strap sensor. If sensor is
working correctly Operation Button LED will flash 4 times.
8.
Using your finger, press and hold the feedwheel lever switch. If working correctly the
Operation Button LED will illuminate 2 times.
9.
Lastly, remove the small piece of strap from under the feedwheel. Operation Button LED will
flash 3 times indicating the home switch is working.
23