Keysight Technologies N9355B Operating And Service Manual page 11

Power limiter
Hide thumbs Also See for N9355B:
Table of Contents

Advertisement

Table 2-3
Keysight Model Number
Frequency Range
Insertion Loss
Return Loss (VSWR)
Maximum Continuous Input Power
Limiting Threshold
Maximum Leakage Power
Maximum DC Voltage
Turn On Time
Impedance
Dimension
Connectors
1 Return loss specification from 10 MHz to 30 MHz is 8.5 dB (VSWR 2.2).
2 At maximum continuous power.
3 Device is suitable for bilateral operation. Input and output ports may be interchanged.
Keysight N9355x and N9356x Power Limiter Operating and Service Manual
RF Specifications for N9355C and N9356C Power Limiters
1
2
o
@25
C
o
@85
C
Length
Diameter
3
N9355C
10 MHz to 26.5 GHz
<2.00 dB
>15 dB (1.43)
1 W
10 dBm (typical)
24 dBm
30 V
16 V
<100 ps
50 Ohm (nominal)
2.17 in. (55.2 mm)
0.55 in. (14.0 mm)
3.5 mm
Specifications
2
N9356C
<2.25 dB
4 W
25 dBm (typical)
27 dBm
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

N9355cN9356cN9355fN9356b

Table of Contents