Installer
To assure you install this model easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave
these instructions inside the fountain for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.
3/8" O.D. UNPLATED
1/4" O.D. TUBE
COPPER TUBE CONNECT
WATER INLET
COLD WATER SUPPLY
TO CHILLER
NOTE: WATER FLOW
DIRECTION
FIG. 1
HCRFERQ - B
HCRF - ER
IMPORTANT
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
FIG. 2
97885C (Rev. E - 7/07)

Advertisement

loading

Summary of Contents for Halsey Taylor HCRFERQ-B

  • Page 1 HCRFERQ - B Halsey Taylor Owners Manual Refrigerated Fountain with Back Panel HCRF - ER Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
  • Page 2 HCRFERQ - B HCRF-ER ROUGH-IN LEGEND: A = 1/4" O.D. TUBE - WATER OUTLET CONNECTION B = 3/8" O.D. TUBE - WATER INLET CONNECTION C = 1-1/4" O.D. WASTE TUBE D = ELECTRICAL INLET ON CHILLER FIG. 3 97885C (Rev. E - 7/07) PAGE 2...
  • Page 3 HCRFERQ - B HCRF - ER COOLER INSTALLATION 1. Install remote chiller. Remove front panel of chiller. Remove and discard cardboard inner pack from between compressor and side panel. Slide chiller onto the shelf and position it to the left within the guides on the shelf. NOTE: Building construction must allow for adequate air flow on both sides, top, and back of chiller.
  • Page 4 HCRFERQ - B PARTS LIST ITEM NO. PART NO. DESCRIPTION 40575C Strainer 15005C Retaining Nut Push Button 45662C Push Button Sleeve 45737C 50986C Regulator Holder 51544C Bubbler 56159C Bubbler Nipple Assy Regulator 61313C Set screw - #6-32 x .31" 70022C 112627543890 Screw - #10-24 X .50 PHTC 55996C...