18 Strip the end of the wire and connect the
provided white wire using a female terminal.
Genie part numbers 1541GT, 13826GT.
19 Crimp on a provided female terminal to the
loose end of the white wire.
20 Locate the black wire in the junction box and
crimp on a provided female terminal.
Note: Models with a no AC power outlet option, do
not use the black wire with the wire cap installed.
21 Install the platform controls wire assembly into
the junction box. Genie part number
137736GT.
22 Connect the wiring in the junction box. Refer to
the Wiring Diagram.
23 Install the AC power outlet. (if equipped)
24 Install the junction box cover set aside.
25 Using the platform controls harness mounted
to the platform as a guide, secure the wire
assembly installed in the junction box to the
platform using cable ties. Genie part number
28443GT.
26 Disconnect the platform controller and remove
the old platform controls harness from the
platform and discard.
16
27 Mount the contact alarm assembly to the
platform. Refer to the Platform Mounting
Location and Harness Routing.
28 Connect the platform controls wire assembly to
RD
the contact alarm using the contact alarm
harness. Genie part number 1293398GT.
WH
BL
29 Secure the harnesses to the platform using the
provided cable ties.
OR
30 Connect the platform controller the platform
BR
harness.
31 Update the control system software (if
required). Refer to the Software Update
WH
section.
BK
Lift Guard™ Contact Alarm