Qpw (Video Adjustment Data Of The Panel); Qpm (Pulse Meter Value) - Pioneer PDP-5010FD Service Manual

Plasma display system
Hide thumbs Also See for PDP-5010FD:
Table of Contents

Advertisement

5

9.3.5 QPW (VIDEO ADJUSTMENT DATA OF THE PANEL)

The command QPW is for acquiring the factory-preset data about the video of the panel.
Command
Effective Operation
Format
Modes
[QPW]
All operations
Data Arrangement
ECO
1
Drive sequence
2
Standard/nonstandard
3
Type of ABL/WB tables
4
ABL adjustment value
5
R-HIGH adjustment value
6
G-HIGH adjustment value
7
B-HIGH adjustment value
8
R-LOW adjustment value
9
G-LOW adjustment value
10
B-LOW adjustment value
11
R gamma setting
12
G gamma setting
13
B gamma setting
14
Streaking correction
15
Center luminance correction
16
Reserved
17
WB interlocked with APL
18
Transition of protective operations
19
Reserved
20
CS

9.3.6 QPM (PULSE METER VALUE)

The command QPM is for acquiring the accumulated number of pulses of the panel.
Command
Effective Operation
Format
Modes
[QPM]
All operations
Data Arrangement
ECO
1
Pulse meter B 1
2
Pulse meter B 2
3
Pulse meter B 3
4
Pulse meter B 4
5
Pulse meter B 5
6
CS
5
6
Function
To acquire data on the video setting value Return data: 3 (ECO) + 40 (DATA) + 2 (CS) = 45 Byte
Output
Data
Example
Length
3 byte
QPW (fixed)
3 byte
60V
1 byte
S
2 byte
T1
3 byte
128
3 byte
256
3 byte
256
3 byte
256
3 byte
512
3 byte
512
3 byte
512
2 byte
07
2 byte
07
2 byte
07
1 byte
0
1 byte
1
1 byte
1 byte
0
1 byte
0
∗∗
2 byte
2 byte
39
Function
To acquire data on the accumulated number of pulses Return data: 3 (ECO) + 40 (DATA) + 2 (CS) = 45 Byte
Data
Output Example
Length
3 byte
QPM (fixed)
8 byte
00000000
8 byte
00000000
8 byte
00000000
8 byte
00000000
8 byte
00000000
2 byte
6E
PDP-5010FD
6
7
1: Drive sequence
3: Type of ABL/WB tables
48V Video 48 Hz
50V Video 50 Hz
11, 12, 13: RGB Gamma setting
60V Video 60 Hz
72V Video 72 Hz
75V Video 75 Hz
15: Center luminance
60P PC 60 Hz
70P PC 70 Hz
2: Standard/
nonstandard
S
Standard
17: WB interlocked with APL
N
Nonstandard
14: Streking
correction
0
OFF
1
ON
18: Transition of brightness by
7
8
Remarks
n
n: 1 to 4
n
00 to 31
correction
0
OFF
1
ON
2
ON (interlocked with APL)
0
OFF
1
ON
2
WB interlocked ON/γ OFF
3
WB interlocked OFF/γ ON
protective operations
0
Upper limit state for brightness
1
Brightness being reduced
2
Lower limit state for brightness
3
Brightness being increased
Remarks
8
A
B
C
D
E
F
159