5
Recovery flowchart (1-4)...Changing the VOL OFFSET setting voltage
[From the Main flowchart (1) / Recovery flowchart (1-3)]
RST MASK 03 (Green)
Gradually decrease the VOL OFFSET value until disappear the
discharge (dead cell).
The VOL OFFSET value must be 117 or greater.
Current VOL OFFSET < 117?
Display RST MASK 12 (Light blue). / [MKS S62]
Set VOL OFFSET to the current setting value minus 112. / [VOF ***]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Display RST MASK 10 (Pink). / [MKS S60]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Set VOL OFFSET to the current setting value plus 64. / [VOF ***]
Determine the current VOL OFFSET setting value as the final value.
[To the Main flowchart (2)]
5
6
Yes
No
Yes
No
Yes
No
PDP-5010FD
6
7
Replacement of abnormal circuits or
re-replacement of the panel required
Replacement of abnormal circuits or
re-replacement of the panel required
Replacement of abnormal circuits or
re-replacement of the panel required