The second group of errors – errors involving a failure within the power supply are described below:
The "PWM ACTIVATE ERR" error is an internal error of the power supply. This is usually caused by a component failure. To
reset the power supply simply press the Output On/Off button. If the error reoccurs the power supply must be repaired by the
factory.
The "12V BIAS ERR" error is an internal error of the power supply. This is usually caused by a component failure.
power supply simply press the Output On/Off button. If the error reoccurs the power supply must be repaired by the factory.
The "3.3V BIAS ERR" error is an internal error of the power supply. This is usually caused by a component failure.
power supply simply press the Output On/Off button. If the error reoccurs the power supply must be repaired by the factory.
The "PFC FAILURE" error is an internal error of the power supply. This is usually caused by a component failure.
power supply simply press the Output On/Off button. If the error reoccurs the power supply must be repaired by the factory.
The "HS TEMP ERROR" error indicates an overtemperature of the main heatsink. This is usually caused an ambient temperature
over 40C.
To reset the power supply simply press the Output On/Off button. If the error reoccurs and the ambient temperature
is within specifications the power supply must be repaired by the factory.
40
Output error
Enable to reset
12v bias err
Enable to reset
3.3v bias err
Enable to reset
Pfc failure
Enable to reset
Hs temp error
Enable to reset
To reset the
To reset the
To reset the

Advertisement