Operating Elements & Connections; Front Panel; Rear Panel - Omnitronic PAP Series User Manual

Hide thumbs Also See for PAP Series:
Table of Contents

Advertisement

Available languages

Available languages

4
OPERATING ELEMENTS & CONNECTIONS

Front Panel

No.
Element
1
Power on/off
2
Level control
3
SIGNAL LED
4
Power LED
5
CLIP LED
6
FAULT LED

Rear Panel

No.
Element
7
Screw connectors 70 V/100 V
8
Screw connectors 4-16Ω
9
Screw connectors COM
10
Fuse holder
11
INPUT jack
12
LINK feed-through output
13
Mains cable
Function
Turns the amplifier on and off
Adjusts the overall level
Lights up when a signal is present at the input
Lights up when the amplifier is turned on
Lights up in case of overload
Lights up with activated protective circuit:
• for a few seconds after switching-on unit the speaker outputs are ready
for operation
• during operation when the protective circuit has switched off the speakers
in case of a defect
Function
For connecting 70 V and 100 V speakers
For connecting 4-16 Ω speakers
Common ground connection for all speakers
Only replace the fuse when the device is disconnected from mains. Only
use fuses of the same rating and power. The correct fuse value is specified
on the rear panel.
Input (optionally XLR or 6.3 mm jack) for the balanced connection to units
with line level
Output (optionally XLR or 6.3 mm jack) for connection of a further amplifier
For connection to a mains socket