Layout, Mounting And Installation - Q CELLS SL Series Installation And Operation Manual

Cigs solar modules
Table of Contents

Advertisement

5 LAYOUT, ASSEMBLY AND INSTALLATION
SAFETY INSTRUCTIONS
WORK SAFETY
REGULATIONS
FIRE PROTECTION
WARNING! Damaged module components may cause risk of fire hazard!
• Only install undamaged solar modules.
• Ensure that the junction box, cable and connectors are undamaged prior to installation.
• Do not open the junction box under any circumstances.
• Always store the solar modules securely in a dry place. The packaging is not
weather-resistant!
• The voltage of a Q.SMART module is higher at lower temperatures and / or higher irradia-
tion than the Standard Test Conditions (25 °C, 1000 W/m²). This must be considered so
that the overall voltage of the module strings does not exceed 1000 VDC (according to IEC
61646 / IEC 61730 standard) or 600 VDC (according to UL 1703 standard).
• Integrate the solar system in the existing lightning protection system, in accordance with
the local regulations.
• Do not install or perform maintenance the modules in strong wind or rain. We recommend
that mounting and installation only be performed in dry weather.
• During mounting on buildings, there is a danger that tools, mounting materials or solar
modules can fall and injure people. Block off the danger area on the ground before begin-
ning the assembly work.
• Warn people near the danger area or in the building. Keep children away from the instal-
lation site.
• Carry out wiring work in such a way that people are not endangered and that no damage
can occur.
• Protect all parts of the module during transport and installation from mechanical stresses
(e.g. from pressure, tension, torsional stress). Ensure that the bend radius of the connec-
tion cables is kept greater than 60 mm at all times.
• The solar modules, especially the connectors and tools, must be dry during installation.
In order to ensure safe mounting, familiarize yourself with the national regulations for work
safety and accident prevention.
The regulations and safety instructions applicable for the installation of electrical devices and
systems must be observed.
Also observe valid regulations and safety instructions concerning the fire protection classifica-
tion for rooftop installations. The module belongs to fire protection class C.
INSTALLATION AND OPERATION MANUAL FOR CIGS SOLAR MODULES Q-CELLS SE
7

Hide quick links:

Advertisement

Table of Contents
loading