4.2 Modbus TCP/RTU Addressing

4.2.1 I/O Data Addressing

The GW-7433D provides a piece of the internal memory for saving I/O
data. The table 4-2 shows the detail information of the memory type, data type,
address, and so on. After using GW-7433D Utility to configure the mapping
information of the CANopen slaves, users can get the mapping table between
the Modbus address and CANopen data. The information of the Modbus
memory assignment and corresponding data type are shown below.
Memory
Command
Type
Start Addr
DI
0000h
DO
0000h
AI
0000h
AO
0000h

4.2.2 Special Data Addressing

The GW-7433D supports special data such as the error status of the
CANopen slave, reset command, and so on. The table 4-3 shows the details of
these special data addresses.
Type
Address
AI
Max. AI address + n
*1 *2
AI
Max. AI address + N + 1
*3
AI
Max. AI address + N + 2
*3
GW-7433D MODBUS TCP/RTU to CANopen Gateway User Manual
(Version 2.1.0, Aug/2019)
PLC
Max
Start Addr
channel
00001h
3072
10001h
3072
30001h
640
40001h
640
Table 4-2: I/O Data Addressing
Read n
*4
Read the GW-7433D's error status.
*4
Read the GW-7433D's CAN status.
*5
Support CANopen
Data Type
Boolean
Boolean
Byte, Word, 4-byte
Byte, Word, 4-byte
Description
th
CANopen slave's error status.
Support
Function
2
1, 5, 15
4
3, 6, 16
26