System Parameters Screen
The System Parameters Screen contains a scrollable list of
system operating parameters specific to the selected circuit.
You are able to scroll the list and tap any parameter to adjust
its value. Please reference Pro Refrigeration's CR110 manual
for a list of factory recommended settings specific to your
system's configuration. See Figure 4-6.
Figure 4-6 System Parameters Screen
•Previous Button: The Previous button will take you
back to the Component Test Screen.
•Next Button: The Next button will take you to the
Home Screen.
•Parameter List: Tap any setting in the list and you
will be given a numerical pad to adjust it's value.
App Menu
The App Menu is at the top left-hand corner of the screen
and provides a number of options that can be configured. To
access the drop down app menu tap the word App. Each op-
tion is discussed in detail below. See Figure 4-7.
Figure 4-7 App Menu
•Set INF: This option allows you to specify the INF
file that matches the number of circuits on your chiller
system. By default you should have configurations on
the storage card for 1 to 5 compressors. If you need a
configuration not provided please contact Pro Refrig-
eration's technical support. To change the INF file tap
the Set INF option in the App menu, an open dialog
will popup, tap the Storage Card icon to navigate to its
directory, you can now tap twice to select the proper
INF for your system from the options provide on the
storage card (ex "Pro C1 revB ver04B", "Pro C1C2
revB ver04B", "Pro C1C2C3 revB ver04B", etc. Where
C# corresponds to the number of compressors on your
system). See Figure 4-8 below.
Figure 4-8 Load INF File Dialog
•Set Update Rate: This setting controls how often in
seconds the TS110 display will request data from the
CR110 controller. By taping this option you will be
given a numerical keypad to change the Update Rate.
•Set_Comm Alarm Delay: This settings controls the
amount of time in seconds that the TS110 will wait for
a response from the CR110 controller before going into
a Comm Alarm state.
•Set UDP Port: The UDP port by default is set to 4001
and should not be modified unless instructed to by
Pro Refrigeration. This setting is used for communica-
tion with the remote monitoring software used by Pro
Refrigeration's technical support.
•Set COM 1: COM 1 is not used at this time.
•Set COM 2: COM 2 is not used at this time.