Electrical Installation & Plumbing - BainUltra GEYSAIR Addendum To The Owner's Manual

Table of Contents

Advertisement

T U R B I N E | g e ys a ir
t m
tur Bin e witH g e y sa i r - el eCt riCa l in s tallati on & Plum Bi n g
grounding
the electrical system must be connected to an
independent circuit protected by a new 20 aMp
class a ground fault circuit interrupter (gfci)
and another one of 15 aMp for additonal options.
this electrical circuit must imperatively be grounded.
canaDa only: for permanently connected units.
a green-colored terminal (or a wire connector marked g,
gr, ground or grounding) is provided within the terminal
compartment (not applicable if unit supplied with an elec-
tric plug). to reduce the risk of electrocution, connect this
terminal or connector to the grounding terminal of your
electric service or supply panel with conductor equivalent in
size to the circuit conductors supplying the equipment and
be 12 awg or more. install this unit in aCCordanCe
with the Canadian eleCtriCal Code, Part 1.
aCCess
a service access is necessary. minimum dimensions
are: 22" x 18" (55 cm x 46 cm) to properly reach all
electrical components of the system.
PlumBing
www.bainultra.com
Printed in Canada. Copyright © september 2012 Bainultra inc. all rights reserved. 45100169
some products, specifications, and services mentioned in this manual are described
in pending patent applications or are protected by patents.
a d den dum t o the owner's manual
tURbIne wIth GeYsaIR
electrical installation & pluMBing
the turbine is connected to a 120V circuit.
all electrical connections must be carried out by
a certified electrician in accordance with local
electrical requirements and codes. special attention
must be given to installation of bath' s power circuit,
and more particularly to the following points:
ConneCtions
the inmix module (Chromatherapy) of the electronic control and
the turbine must be easily accessible at all times. make all connec-
tions as indicated on diagram below. ensure that power circuit
is disabled before proceeding with any electrical connec-
tions. electrical cable feeding bath must be at least n° 12 awg
caliber. turbine must be connected to its own circuit, which,
in turn must be connected directly in breaker panel without
any interrupters or dimmer switches. Canada only: the junc-
tion box must be attached to the wall at the height of at least
1 1/2" (3.8 cm) from the ground.
the geysair hose must be connected to the hot water supply
by a qualified plumber. a 3/8 inch male or 1/2 inch nPt hose bibb
is supplied. for optimal performance, keep hose length to
a minimum. set temperature on hot water heater no higher than
140°f/60°C. for all the houses having to deal with special
water conditions (hard, rust, sulfur, etc) the homeowner
should already be aware of the specific measures that should
be taken for all his other appliances using water. the geysair
does not need other measures than that.
supersedes page 27 of owner' s Manual