(1) Wear insulated gloves and rotate the handle of the service plug grip and remove the service
plug grip as indicated by the arrows, in the order shown in the illustration.
2
1
11. REMOVE CONNECTOR COVER ASSEMBLY
Caution:
Wear insulated gloves.
(1)
Remove the 2 bolts and connector cover assembly
from the inverter with converter assembly.
Notice:
Make sure to pull the connector cover assembly
straight up, as a connector is connected to the bottom
of the cover.
12. CHECK TERMINAL VOLTAGE
Caution:
Wear insulated gloves.
Notice:
Do not allow any foreign matter or water to enter the
inverter with converter assembly.
(1)
Using a voltmeter, measure the voltage between the
terminals of the 2 phase connectors.
Standard Voltage: 0 V
Hint:
Use a measuring range of DC 750 V or more on the
voltmeter.
for LHD:
for RHD:
for LHD:
for RHD:
24
3