Do you have a question about the currenza c2 and is the answer not in the manual?
Questions and answers
Tony
February 26, 2025
how do you make the display brighter on a NRI blue C2 coin mechanism?
1 comments:
Mr. Anderson
February 26, 2025
To increase the display brightness on an NRI Blue C2 coin mechanism, follow these steps:
1. Enter the OTHER SETTINGS submenu. 2. Navigate to DISPLAY CONTRAST. 3. Adjust the contrast value by selecting and modifying the required digit. 4. Confirm and lock the new contrast value in memory. 5. Return to the main menu or operating mode.
This process allows you to change the display contrast, which affects brightness.
SRG – c service work ABLE OF CONTENTS Table of contents About this short reference guide Text conventions Additional technical documentation Work on the change tubes Displaying the current coin stocks in the tubes (inventory) 7 Giving out single/several coins Giving out single coins Giving out several coins after another Emptying tube cassette...
Page 4
SRG – c service work ABLE OF CONTENTS Firmware update Displaying current firmware versions Updating firmware Downloading new firmware and FW update PC application from the internet Installing HenriFlash Loading new firmware in HENRI Installing new firmware in the coin changer Audit (option) Checking audit data with HENRI Which audit data is recorded and in what structure?
In order to be able to use the whole functional range of the devices safely as well as to configure all possible functions, all short reference guides for the NRI changer currenza c and HENRI setting module must be read carefully (PDF download at www.nri24.com).
SRG – c service work BOUT THIS SHORT REFERENCE GUIDE 1 2 3 ... Requests to perform an action are numbered in another typeface. are set in small capitals. ISPLAY TEXTS BUTTONS and MENU ITEMS are shown in bold capitals. [1/2] Reference to a figure.
SRG – c service work ORK ON THE CHANGE TUBES Work on the change tubes In this chapter you will learn how to • display the current tube counters/levels (inventory) • pay out single coins • empty the change tubes (completely/up to a certain filling level (float level)) •...
SRG – c service work ORK ON THE CHANGE TUBES The security stock per tube possibly configured is not displayed (cp. separate configuration short reference guide). Pressing the inventory key A, B, C, D, E, or F briefly would now pay out single coins and holding down the key would pay out several coins one after another from the appropriate tube.
SRG – c service work ORK ON THE CHANGE TUBES Giving out several coins after another To give out several tube coins: Hold down the corresponding key A–F for approx. five seconds. The tube gives out several coins. Press any other key A–F. The coins will stop being paid out.
SRG – c service work ORK ON THE CHANGE TUBES Emptying all change tubes up to certain filling level (float level) If a float level is configured for each change tube, the change tubes can be emptied up to the number of tube coin set in the float levels. (Cp. separate configuration short reference guide) To empty all change tubes up to the float level: Connect c...
SRG – c service work ORK ON THE CHANGE TUBES Refilling change ... The coin changer can be provided with change either by inserting the tube coins when the empty tube cassette is installed, or you remove the empty tube cassette and fill the cassette direct..
SRG – c service work ORK ON THE CHANGE TUBES blue/c white/orange Connect c white/orange with HENRI setting module (plug HENRI RJ-45 connector into coin changer socket in the upper right hand corner, cp. separate HENRI short reference guide). HENRI switches to c² mode automatically and displays the current change stock if there is no error.
SRG – c service work ORK ON THE CHANGE TUBES The corresponding tube counter counts the coins accepted. The tubes are full when the • full sensor is covered, • configured filling level limitation has been reached or • configured float level has been reached. (Cp.
Page 14
SRG – c service work ORK ON THE CHANGE TUBES If all tubes are full: Press -key again. The green LED lighting up shows that the changer is no longer in tube filling mode, but back in operating mode. If no coins are inserted in a 30-second time period, the changer returns to operating mode, without the -key being pressed again.
SRG – c service work ORK ON THE CHANGE TUBES ... by filling the tube cassette direct ... You can also remove the empty tube cassette and refill it direct. Or you have filled a replacement cassette beforehand and only replace the empty cassette on site.
SRG – c service work ORK ON THE CHANGE TUBES Fig. 1: Removing and reinstalling the tube cassette ... with counted coins (float level) If the change tubes are supposed to always be filled with a certain number of coins, this number of coins (float level per tube) as well as the automatic tube counter programming must be set in the coin changer.
Page 17
SRG – c service work ORK ON THE CHANGE TUBES blue/white/orange Connect c white/orange with HENRI setting module (plug HENRI RJ-45 connector into coin changer socket in the upper right hand corner, cp. separate HENRI short reference guide). HENRI switches to c² mode automatically and displays the current change stock if there is no error.
Page 18
SRG – c service work ORK ON THE CHANGE TUBES Reinstall full (replacement) tube cassette: • Insert cassette in upper and lower housing guides (Fig. 1, B). • Push cassette into the housing. • Press cassette down and let it engage in the upper and lower housing guides (audible click) (Fig.
Page 19
SRG – c service work ORK ON THE CHANGE TUBES The automatic tube counter correction must be deactivated so that the accurately set tube counters will not be corrected according to the filling level sensors. It is possible that the changer reports less change than refilled: In this case the coin changer is set so that the tube counter readings are transmitted to the VMC without security stock (see separate configuration short reference guide).
SRG – c service work ORK ON THE CHANGE TUBES Optimising coin movement in the tubes The coin changer currenza c² supports you in setting the tube parameters optimally, i.e. it provides analyses guaranteeing that the tube cassette not only collects as much cash as necessary but also as less as possible depending on the installation site.
SRG – c service work ORK ON THE CHANGE TUBES Comparing in and out of tube coins The required menu item P has already been AYOUT STATISTICS selected. Press OK key to confirm your selection: The changer/HENRI displays for each tube how many per cent of the accepted coins have been paid out.
SRG – c service work ORK ON THE CHANGE TUBES Analysing the coin movement in the tubes and set tube parameters optimally Press B key "down-arrow" to select submenu S TATUS OF ANALYSIS Press OK key to confirm your selection: The analysis is running.
SRG – c service work OKEN CONFIGURATION Token configuration This chapter describes how to • teach a new token in a coin channel, • configure this token either as free vend token or as value token, and • erase a token configuration Teaching token in a coin channel The coin changer currenza c²...
Page 24
SRG – c service work OKEN CONFIGURATION Press C key to open the S menu: ERVICE Press B key "down-arrow" twice to select submenu T OKEN TEACH Use OK key to confirm your selection: Press OK key again to teach a token. If necessary, use B key "down-arror"/A key "up-arror"...
A, e.g., can be free vend token and token B value token. Whether a token is directed to the return area or into the cash-box, is customised by NRI. Configuring token values Taught tokens can either be configured as free vend tokens (see next section) or as value tokens.
Page 26
SRG – c service work OKEN CONFIGURATION Press E key to open the S menu: ETTINGS Press B key "down-arrow" until submenu C is selected. OIN SETTINGS Use OK key to confirm your selection. Press B key "down-arrow" until submenu T is selected: OKEN Use OK key to confirm your selection:...
SRG – c service work OKEN CONFIGURATION Set token value: • Use D key (right arrow)/C key (left arrow) to highlight the place of the token value to be changed. • Use A key (up-arrow)/B key (down-arrow) to configure the value of the place highlighted.
SRG – c service work OKEN CONFIGURATION Erasing token configuration If a configured token is no longer to be accepted for payment, as the coin channel is to be programmed with another token you are able to erase the present token configuration: Connect c green/white/orange with HENRI setting module (plug HENRI RJ-45 connector into coin changer socket in the upper right...
SRG – c service work IRMWARE UPDATE Firmware update In this chapter you learn how to update the c firmware by means of the HENRI setting module. The currenza c is fitted with three microcontrollers the firmware (FW) of which may be updated: •...
Downloading new firmware and FW update PC application from the internet HenriFlash can be downloaded from the NRI website (www.nri24.com) along with the current FW using your customer password. If you have not registered yet: Open NRI website on the internet (www.nri24.com).
SRG – c service work IRMWARE UPDATE Loading new firmware in HENRI Connect the USB cable provided to the PC. Select directory started when installing and start "HenriFlash.exe". Select FW to be updated in the start window (c² coin validator, c² coin changer, c²...
SRG – c service work IRMWARE UPDATE Installing new firmware in the coin changer Connect c with HENRI setting module (plug HENRI RJ-45 connector into coin changer socket in the upper right hand corner, cp. separate HENRI short reference guide). HENRI switches to c²...
SRG – c service work UDIT OPTION Audit (option) If the currenza c is fitted with an optional internal audit module, all audit data is collected and evaluated by the changer, so that it may be read out using a mobile data retrieval unit (MDE) or rather printed using a mobile printer for audit purposes.
SRG – c service work UDIT OPTION General data The submenu G contains all general audit data of the coin ENERAL DATA changer currenza c²: • M (10-digit) ACHINE NUMBER • N UMBER OF PRINTOUTS READOUTS – since installation – since initialisation –...
SRG – c service work UDIT OPTION • F REE VENDS WITH TOKENS – since initialisation – since last readout – cycles (since initialisation, since last readout) • T EST VENDS – since initialisation – since last readout – cycles (since initialisation, since last readout) •...
Page 36
SRG – c service work UDIT OPTION • C OINS TO TUBE IN MANUAL FILLING MODE – since initialisation – since last readout • C OINS PAID OUT MANUALLY – since initialisation – since last readout • C ASH OVERPAY –...
Page 37
SRG – c service work UDIT OPTION Flow of money using card system The audit data for in and out of cards is listed in the C submenu: ASHLESS DATA • D EBITED FROM CASHLESS – since initialisation – since last readout –...
SRG – c service work UDIT OPTION Displaying audit data The following abbreviations are used to display the audit data: "Inst." = since installation "s.Ini." = since initialisation "s.l.R." = since last readout Connect c green/white/orange with HENRI setting module (plug HENRI RJ-45 connector into coin changer socket in the upper right hand corner, cp.
OPTION Reading out audit data using the IrDA interface If your coin changer has no integrated IrDA interface, you will require an NRI infrared adapter as an optical interface (cp. also product accessory pages at www.nri24.com) in order to be able to read out the audit data via an infrared data retrieval unit (MDE).
Printing out audit data using a mobile printer The changer is equipped with an interface (9-pole D-Sub plug) for connecting a printer (e.g. NRI printer G-55.0510, cp. also product accessory pages at www.nri24.com). Depending on the printer connected, the printout is either activated immediately or after a start button has been pressed.
The currenza c memorises statistical data of turnovers, cash flow and errors, which can be read out by an NRI service technician. In case the HENRI memory is full and all relevant data has been transmitted to a PC the statistics can be erased.
SRG – c service work EADOUT OF STATISTICAL DATA Press A key again to save the statistical data. The bottom line displays the free space left on the HENRI memory (e.g. "001/128"): If HENRI displays "128/128", the memory is full and the stored statistics must be erased (see next section).
Page 43
SRG – c service work EADOUT OF STATISTICAL DATA First press the B key and then the E key if you really want to delete all statistics, if not, use the F key to cancel the process: National Rejectors, Inc. GmbH, Buxtehude...
SRG – c service work NDEX Index A–F keys 8, 9 Danger 5 Accentuations in the text 5 Delete Acceptance band, token statistical data 42 erase 28 token configuration 28 narrorw 23 Display texts 6 wide 23 Disposal 5 Attention 5 Documentation, additional 6 Audit data dsp (file extension) 30...
Page 45
Menu Status of analysis 22 items 6 Summary, chapter 5 texts 6 Symbols in the text 5 mot (file extension) 30 New version 32 Notes 5 Nri(64)HidAPI.dll 30 Operating instructions, additional 6 Optical adapter 39 National Rejectors, Inc. GmbH, Buxtehude...
Page 46
SRG – c service work NDEX Teach tokens 23 Text conventions 5 Token audit data 34 erase 28 for payment/free vend 25 teach 23 value 26 Tube coins, optimise stock 20 filling level 13, 18 Tube cassette empty 9 up to float level 10 fill by inserting coins 11 direct filling 15...
Need help?
Do you have a question about the currenza c2 and is the answer not in the manual?
Questions and answers
how do you make the display brighter on a NRI blue C2 coin mechanism?
To increase the display brightness on an NRI Blue C2 coin mechanism, follow these steps:
1. Enter the OTHER SETTINGS submenu.
2. Navigate to DISPLAY CONTRAST.
3. Adjust the contrast value by selecting and modifying the required digit.
4. Confirm and lock the new contrast value in memory.
5. Return to the main menu or operating mode.
This process allows you to change the display contrast, which affects brightness.
This answer is automatically generated