Operation Data - Toshiba RAS-10YAV-E Service Manual

Toshiba air conditioner service manual
Hide thumbs Also See for RAS-10YAV-E:
Table of Contents

Advertisement

6-2. Operation Data

<Cooling>
Temperature
condition (°C)
Model name
Indoor
Outdoor
10YKV-E
27/19
35/–
13YKV-E
<Heating>
Temperature
condition (°C)
Model name
Indoor
Outdoor
10YKV-E
20/–
7/6
13YKV-E
NOTES :
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
(2) Connecting piping condition : 5 m
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
T2 (°C)
0,8 to 1,0
9 to 11
42 to 44
0,8 to 1,0
8 to 10
46 to 48
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
T2 (°C)
3,5 to 3,7
42 to 44
2 to 4
2,5 to 2,7
50 to 52
0 to 3
– 20 –
Indoor fan
Outdoor fan
mode
mode
High
High
High
High
Indoor fan
Outdoor fan
mode
mode
High
High
High
High
Compressor
revolution
(rps)
56
85
Compressor
revolution
(rps)
70
97

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-10ykv-eRas-13ykv-eRas-13yav-e