9-1-2. Optional Installation Parts
Part
• Secure the outdoor unit with the fixing bolts and nuts if the
Parts name
Q'ty
code
Refrigerant piping
Each
• Use ø8 mm or ø10 mm
A
Liquid side
: Ø6,35
one
Gas side
: Ø9,52
• If it is necessary to drain
Pipe insulating material
B
1
(Polyethylene foam, 6mm thick)
Each
C
Putty, PVC tapes
one
9-1-3. Accessory and Installation Parts
Part
Part
Part name (Q'ty)
No.
No.
1
5
Mounting screw Ø4 x 25 x 6
Installation plate x 1
2
6
Purifying filter x 1
Wireless remote controller x 1
3
7
Battery x 2
Deodorizing filter x 1
4
8
Pan head wood screw Ø3,1x 16 x 2
Remote controller holder x 1
9-1-4. Installation/Servicing Tools
Changes in the product and components
In the case of an air conditioner using R410A, in order to prevent any other refrigerant from being charged
accidentally, to service port diameter of the outdoor unit control valve (3 way valve) has been changed.
(1/2 UNF 20 threads per inch)
• In order to increase the pressure resisting strength of the refrigerant piping flare processing diameter and
size of opposite side of flare nuts has been changed.
(for copper pipes with nominal dimensions 1/2 and 5/8)
New tools for R410A
New tools for R410A
Applicable to R22 model
× × × × ×
Gauge manifold
× × × × ×
Charge hose
¡
Electronic balance
for refrigerant charging
× × × × ×
Torque wrench
(nominal diam. 1/2, 5/8)
¡
Flare tool (clutch type)
——
Gauge for projection adjustment
¡
Vacuum pump adapter
× × × × ×
Gas leakage detector
• Incidentally, the "refrigerant cylinder" comes with the refrigerant designation (R410A) and protector coating
in the U. S's ARI specified rose color (ARI color code: PMS 507).
• Also, the "charge port and packing for refrigerant cylinder" require 1/2 UNF 20 threads per inch correspond-
ing to the charge hose's port size.
Fixing bolt arrangement of outdoor unit
unit is likely to be exposed
600
to a strong wind.
Suction side
115
anchor bolts and nuts.
the defrost water attach
drain nipple to the bottom
Diffuser
plate of the outdoor unit
Fig. 9-1-2
before installing it.
Part name (Q'ty)
Owner's manual
Others
Installation manual
This model is not equipped with
an extention drain hose.
Option :
For the extention drain hose, use
an optionally available RB-821SW
or commercially available one.
Changes
As pressure is high, it is impossible to measure by means of
conventional gauge. In order to prevent any other refrigerant from
being charged, each port diameter has been changed.
In order to increase pressure resisting strength, hose materials and
port size have been changed (to 1/2 UNF 20 threads per inch).
When purchasing a charge hose, be sure to confirm the port size.
As pressure is high and gasification speed is fast, it is difficult to read
the indicated value by means of charging cylinder, as air bubbles
occur.
The size of opposite sides of flare nuts have been increased. Incidentally,
a common wrench is used for nominal diameters 1/4 and 3/8.
By increasing the clamp bar's receiving hole, strength of spring in the
tool has been improved.
Used when flare is made by using conventional flare tool.
Connected to conventional vacuum pump. It is necessary to use an
adapter to prevent vacuum pump oil from flowing back to the charge
hose. The charge hose connecting part has two ports-one for
conventional refrigerant (7/16 UNF 20 threads per inch) and one for
R410A. If the vacuum pump oil (mineral) mixes with R410A a sludge
may occur and damage the equipment.
Exclusive for HFC refrigerant.
Exclusive for HFC refrigerant.
9-2. Indoor Unit
9-2-1. Installation Place
• A place which provides the spaces around the
indoor unit as shown in the above diagram.
• A place where there is no obstacle near the air
inlet and outlet.
• A place which allows an easy installation of the
piping to the outdoor unit.
• A place which allows the front panel to be
Drain hole
opened.
CAUTION
• Direct sunlight to the indoor unit wireless
receiver should be avoided.
• The microprocessor in the indoor unit should not
Name
be too close to r-f noise sources.
(For details, see the owner's manual.)
Remote controller
• A place where there are no obstacles such as a
curtain that may block the signal from the indoor
unit.
• Do not install the remote controller in a place
exposed to direct sunlight or close to a heating
source, such as a stove.
• Keep the remote controller at least 1 m apart from
the nearest TV set or stereo equipment.
(This is necessary to prevent image disturbances
or noise interference.)
• The location of the remote controller should be
determined as shown below.
(Side view)
(Top view)
Indoor unit
Reception
Remote
Reception
range
controller
range
: Axial distance
*
Fig. 9-2-1
9-2-2. Cutting a Hole and Mounting
Installation Plate
Cutting a Hole
When install the
refrigerant pipes
from the rear.
The center of the piping slot
is above the arrow.
The center of the pipe
hole is above the arrow.
80mm
Fig. 9-2-2
1. After determining the pipe hole position on the
mounting plate (80 mm
), drill the pipe hole
(ø65 mm) at a slight downward slant to the
outdoor side.
NOTE
• When drilling the wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe
hole brim ring sold separately.
Mounting the Installation Plate
For installation of the indoor unit, use the
paper pattern on the back.
Anchor bolt hole
120mm
65,5mm
Pipe
hole
Pipe hole
Thread
5 Mounting
Indoor unit
screw
Weight
Fig. 9-2-3
When the installation plate is directly
mounted on the wall
1. Securely fit the installation plate onto the
wall by screwing it in the upper and lower
parts to hook up the indoor unit.
2. To mount the installation plate on a
concrete wall with anchor bolts, utilize the
anchor bolt holes as illustrated in the
above figure.
3. Install the installation plate horizontally in
the wall.
CAUTION
When installing the installation plate with
mounting screw, do not use the anchor
bolt hole. Otherwise the unit may fall down
and result in personal injury and property
damage.
Remote
controller
Fig. 9-2-4
5 mm dia. hole
5 Mounting screw
Clip anchor
(local parts)
CAUTION
Pipe hole
Failure to firmly install the unit may result
in personal injury and property damage if
the unit falls.
• In case of block, brick, concrete or similar
type walls, make 5 mm dia. holes in the
wall.
• Insert clip anchors for appropriate
mounting screws.
NOTE
• Install the installation plate using 4 to 6
pieces of mounting screw securing four
corners with screws.
40mm
66mm
65,5mm
1
Installation
plate
Anchor bolt
Projection
15mm or less
Ø4 x 25
Fig. 9-2-5
U